Chapter 5 Maintenance <strong>and</strong> Troubleshooting<br />

Maintenance<br />

The following maintenance is recommended to ensure optimal performance.<br />

Frequency<br />

Yearly<br />

When needed<br />

Maintenance Required<br />

• Check all parameters <strong>and</strong> test points.<br />

• Record data.<br />

• Make adjustments as needed.<br />

• Make sure all cables are mated properly.<br />

• Inspect cables for stress <strong>and</strong> chafing.<br />

• Make sure all retaining screws are tight.<br />

• Replace chassis air filter. Depending on office enviro<strong>nm</strong>ent<br />

cleanliness/filtration, the chassis air filter may require more<br />

frequent servicing.<br />

Carefully clean the module with a soft cloth that is dampened with<br />

mild detergent.<br />

Maintenance Record<br />

It may be helpful to establish a maintenance record or log for this equipment. You<br />

may want to record laser power level, laser temperature readings, laser bias current,<br />

or power supply voltages, as well as the filter change dates.<br />

Large variations in any of the parameters above should be investigated prior to<br />

failure.<br />

98 78-4021716-01 Rev C