External Alarms Connections<br />

External Alarms Connections<br />

Master/Slave Operation<br />

All <strong>Prisma</strong> <strong>II</strong> modules ship from the factory configured as a master. The LCI, TNCS<br />

software, or the ICIM can be used to reconfigure a module as a slave or as<br />

redundant. The <strong>Prisma</strong> <strong>II</strong> Chassis allows for local hard-wired redundancy by using<br />

the ALARM IN <strong>and</strong> ALARM OUT connectors located on the connector interface<br />

panel. A pair of modules can be configured so that if the master fails, the slave takes<br />

over by using the ALARM IN <strong>and</strong> ALARM OUT connectors.<br />

ALARMS IN <strong>and</strong> ALARMS OUT Connector Illustration<br />

St<strong>and</strong>ard <strong>Prisma</strong> <strong>II</strong> Chassis<br />

<strong>Prisma</strong> <strong>II</strong> XD Chassis<br />

ALARMS IN <strong>and</strong> ALARMS OUT Connectors<br />

Every <strong>Prisma</strong> <strong>II</strong> St<strong>and</strong>ard <strong>and</strong> <strong>II</strong> XD chassis provides connectors for external alarms<br />

to <strong>and</strong> from each module slot. These alarm connectors are located on the chassis<br />

connector panel <strong>and</strong> are labeled ALARMS IN <strong>and</strong> ALARMS OUT.<br />