<strong>High</strong> <strong>Density</strong> <strong>Transmitter</strong> Parameters<br />

Configurable Parameters<br />

Parameter<br />

Name (LCI)<br />

ICIM<br />

Abbreviation<br />

Description Values Default<br />

Laser Enable Enable Enables or disables amplifier<br />

operation, i.e., turns the laser on or<br />

off.<br />

Cw Mode CwMode Automatically adjusts the<br />

displayed RF input level by<br />

subtracting 3 dB when CW mode<br />

is on. The RF high alarm is also<br />

disabled when CW mode is on.<br />

Low RF Alarm<br />

Inhibit<br />

LoRFInh<br />

Enables or disables the "RF input<br />

low" alarm.<br />

Master Master Configures the module as master<br />

or slave:<br />

• If set to Master, the transmitter<br />

is controlled only by the<br />

Enable control above.<br />

ON (1) = Enabled<br />

OFF (0) =<br />

Disabled<br />

ON (1) = Enabled<br />

OFF (0) =<br />

Disabled<br />

ON (1) = Alarm<br />

Enabled<br />

OFF (0) = Alarm<br />

Disabled<br />

ON (1) = Master<br />

OFF (0) = Slave<br />

ON (1)<br />

OFF (0)<br />

ON (1)<br />

ON (1)<br />

• If set to Slave, the transmitter<br />

is controlled by a combination<br />

of Enable <strong>and</strong> the external<br />

input CNT_IN_1.<br />

RF Drive Level RFDrive Sets the relative RF drive level into<br />

the transmitter. Only effective<br />

when AGC is off (manual gain<br />

control).<br />

Automatic Gain<br />

Control<br />

OMI Level<br />

Setting<br />

AGC<br />

OMISet<br />

Turns automatic gain control on or<br />

off.<br />

Adjust the offset of optical<br />

modulation index level. Only<br />

effective when AGC is on.<br />

-5.0 dB to +3.0 dB<br />

in 0.5 dB steps<br />

ON (1)<br />

OFF (0)<br />

-8.0 dB to +2.0 dB<br />

in 0.5 dB steps<br />

0.0 dB<br />

OFF (0)<br />

0.0 dB<br />