6. Automatic Playback Redundancy Installation<br />

Or,<br />

click on Browse and browse to the desired computer <strong>in</strong> the network.<br />

Image 6-4<br />

Redundant pair computer name<br />

4. Cont<strong>in</strong>ue with the normal <strong>in</strong>stallation.<br />

DVI switch, technical <strong>in</strong>fo<br />

• Frequency bandwidth: 1.65 Gbps (S<strong>in</strong>gle L<strong>in</strong>k)<br />

• Support<strong>in</strong>g Graphic Resolution: UXGA (1600 X 1200 at up to 85Hz) (1920 X 1080 at up to 60Hz)<br />

• Inputs: Dual DVI-D Female ports<br />

• Output: DVI-D Female port<br />

• Control <strong>in</strong>put: RS232 <strong>in</strong>put<br />

• Infrared Remote Control Included<br />

• Power supply: DC 5V, 2A Adapter <strong>in</strong>cluded.<br />

• Dimensions (W X D X H): 170.2 x 120.7 x 30.9 mm (6.7 X 4.75 X 1.2 Inches)<br />

• Weight: 613g (1.35 lbs)<br />

• HDCP (High-bandwidth Digital Content Protection) Compliant.<br />

RS232 Comb<strong>in</strong>er, technical <strong>in</strong>fo<br />

• Dimensions: 4.01 x 2.00 x 0.9 <strong>in</strong> (10.19 x 5.08 x 2.29 cm)<br />

• Connectors: 3 x DB-9 female, RS-232 DCE configuration<br />

• Power Supply (required): 12-17VDC<br />

• Current Draw: 95 mA<br />

• Operat<strong>in</strong>g Temp: 0-50 °C (32-122 °F)<br />

DVI switch <strong>in</strong>stallation<br />

1. Install a first RS232 Comb<strong>in</strong>er (with its power).<br />

2. Connect a straight RS232 cable from Playback Primary COM2 to port 1 on the first RS232 Comb<strong>in</strong>er.<br />

3. Connect a straight RS232 cable from Playback Standby COM2 to port 2 on the first RS232 Comb<strong>in</strong>er.<br />

4. Connect a Male/Male gender changer on the first RS232 comb<strong>in</strong>er master port.<br />

5. Connect a straight RS232 cable from the Male/Male gender changer on the first RS232 Comb<strong>in</strong>er to<br />

the RS232 <strong>in</strong>put on the DVI Switch.<br />

72 R5976955 <strong>XVS</strong> - 2 14/03/2007