Chapter 1<br />

IX-4EVMC<br />

5. At the sh380 [Iwatsu] DATA:> prompt, type the following in lowercase lettering.<br />

boot<br />

Note:<br />

After typing ‘boot’, do not close the terminal window. If the terminal window is closed, the<br />

Enterprise-CS must be reset.<br />

6. At the Select your System Volume Prompt, select 2.<br />

If 2 is not selected with 5 seconds, the reboot process begins. If this occurs, wait until the IX-<br />

4EVMC reboots. Then, follow the instructions on page 18.<br />

A series of options now displays in the Backup Volume terminal window.<br />

Exit and mount data volume: Factory use only; do not modify.<br />

Run Support Utility: Factory use only; do not modify.<br />

Default programs volume of this unit: This option overwrites all of the program files on the<br />

Programs volume with the program files on the Backup volume. This option only affects<br />

application files. All greetings, messages, and programming of menus, mailboxes, and<br />

integration are left intact.<br />

Default data volume of this unit: This option leaves the application files intact and defaults the<br />

customer data (greetings, messages, and programming of menus, mailboxes, and integration).<br />

Exit to command line with Ethernet: Factory use only; do not modify.<br />

Exit to command line: Factory use only; do not modify.<br />

Reboot: Reboots the IX-4EVMC card.<br />

7. Continue to either the Defaulting Program Volumes (page 20) or Defaulting Data Volumes (page<br />

21) instructions below.<br />