Chapter 3<br />

IX-4VML<br />

IX-4VML Installation into an Existing ADIX APS<br />

Follow these instructions only when installing the IX-4VML into an existing ADIX system.<br />

1. Enter ADIX Database programming mode or access ADIX programming from an ADIX<br />

Attendant key telephone.<br />

2. Go to Class 01 Item 06 – Number of System Station Ports. Increase the number of<br />

system station ports by eight ports for the IX-4VML card.<br />

3. Exit ADIX database programming mode and wait until the memory LED on the CPU<br />

stops flashing.<br />

4. Power down the system.<br />

5. Insert the card into the cabinet.<br />

6. Power up the cabinet.<br />

7. When the system comes up, launch the Iwatsu Programmer.<br />

8. Go to System >> Hardware.<br />

9. Select the card location of the IX-EVMC from the telephone system graphic.<br />

Menu Location<br />

Card Configuration<br />

<strong>Voice</strong>mail Configuration<br />

Card Location<br />

10. Under the Ports screen, define all eight ports as Message Station.<br />

11. Under the Ports screen, configure the function of all eight ports as VML.<br />

12. Upload the configuration changes and wait 10 seconds.<br />

13. Save the database to a secure location.<br />

14. Reset the system.<br />

51