30.10.2014 Views

Omega-Voice VMI Technical Manual (5th Edition) (PN 500175)

Omega-Voice VMI Technical Manual (5th Edition) (PN 500175)

Omega-Voice VMI Technical Manual (5th Edition) (PN 500175)

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Omega</strong>-<strong>Voice</strong> <strong>VMI</strong> <strong>Technical</strong> <strong>Manual</strong><br />

IX-4SEVMC Installation into an Existing ADIX APS<br />

Follow these instructions only when installing the IX-4SEVMC into an existing ADIX APS or ADIX-<br />

M system. The IX-4SEVMC can only be installed in physical ports 97-120 (card 17) in the ADIX<br />

APS or ADIX-M systems.<br />

When adding Stations to the ADIX APS/M, the number of stations being added to the system must be<br />

changed (added) through an Attendant KT in Class 01.06 for Stations.<br />

1. Through an Attendant KT, go to Class 01 Item 06 and increase the station port count by<br />

eight to allow for the increase in station ports for the IX-4SEVMC.<br />

2. Reset the system.<br />

3. Place the IX-4SEVMC card in Make Busy mode using the S1 Make Busy Switch.<br />

4. Insert the card into slot 97-120 in the cabinet.<br />

5. Take the card out of make busy mode.<br />

6. Wait 10 seconds for the IX-4SEVMC card to come out of the make busy condition.<br />

7. Launch the Iwatsu Programmer.<br />

8. Use the Iwatsu Programmer to connect to the system.<br />

9. Download the database: Select, Communication > Download Database from System.<br />

Press Select All and then OK.<br />

10. Select the card location for the IX-4SEVMC from the system graphic.<br />

• The card will appear as a SUBX Card Type.<br />

• The card defaults as eight Station > SLT ports.<br />

30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!