Application requirements<br />

Thickness of base material<br />

hmin<br />

Concrete<br />

dnom<br />

hmin = 100 mm (dnom ≥ 4.5 mm)<br />

Thickness of fastened material<br />

tI ≤ 50.0 mm<br />

Spacing and edge distances (mm)<br />

Steel<br />

tll ≥ 6 mm<br />

Edge distance: concrete Edge distance: concrete<br />

80<br />

Spacing on wood Spacing, edge distances on steel<br />

Corrosion information<br />

The intended use for safety relevant and permanent applications only comprises fastenings<br />

which are not directly exposed to external weather conditions or moist atmospheres. For further<br />

detailed information on corrosion see corresponding chapter in section Direct Fastening<br />

Technology.<br />

11 / 2007 4.137<br />

15<br />

tII<br />

DS