X-AL-H<br />

Recommended setting range<br />

Concrete<br />

No general restrictions existent. Limitations<br />

are depending on application and user<br />

requirements.<br />

Fastener selection<br />

Fastening drywall tracks<br />

dnom<br />

Ls<br />

Ls + 3.5<br />

o 8<br />

Required depth of penetration hET<br />

tI<br />

hET<br />

tII<br />

tI<br />

hET<br />

Steel<br />

4.98 11 / 2007<br />

Shank length, Ls [mm]<br />

67<br />

62<br />

57<br />

52<br />

47<br />

42<br />

37<br />

32<br />

27<br />

6<br />

X-AL-H<br />

8 10 12 14<br />

Steel thickness, tII [mm]<br />

Working beyond the recommended application<br />

range will lead to an increase of the failure<br />

rate.<br />

Required nail shank length:<br />

LS = hET + tl [mm]<br />

Normal weight concrete NWC<br />

hET according to concrete strength:<br />

fcc [N/mm 2 ] 35 50 70<br />

hET [mm] 27 19–22 16–19<br />

Sandlime masonry SLM<br />

hET according to masonry strength:<br />

fcc [N/mm 2 ] 35 50<br />

hET [mm] 27 22<br />

Steel (fu ≤ 690 N/mm 2 )<br />

Use X-AL-H 12 or 14<br />

hET ≥ 10 mm