NPH<br />

Recommended setting range<br />

Types of concrete • Precast and cast-in-place pre-stressed concrete<br />

• Precast and cast-in-place reinforced concrete<br />

Concrete design strength • Minimum C20/25 (fcc = 20 N/mm 2 , fc = 25 N/mm 2 )<br />

• Maximum C45/55 (fcc = 45 N/mm 2 , fc = 55 N/mm 2<br />

• The NPH/DX-Kwik system has been successfully used in<br />

concrete having an in-place cube strength of 70 N/mm 2<br />

Minimum strength/age at • C20/25 concrete must be 28 days old<br />

time of fastening • C45/55 concrete must be 15 days old<br />

Minimum dimensions • Minimum width = 180 mm<br />

of concrete member • Minimum thickness = 160 mm<br />

Fastener selection<br />

Fasteners Tool<br />

Designation Item no.<br />

NPH2-42 L15 40711 DX 76 F15<br />

Cartridge selection and tool energy setting<br />

Cartridges 6.8/18 M blue<br />

Tool energy adjustment by setting tests on site<br />

Fastening quality assurance<br />

Fastening inspection<br />

23<br />

NPH2-42 L15<br />

7.5 -11 mm<br />

1. Insure that pre-drilling is<br />

done with the recommended<br />

bit TX-C-5/23 (Item-<br />

Number: 291934)<br />

2. Check for conformance to<br />

recommendations (detailing<br />

spacing and edge distances<br />

for fastening)<br />

3. Check the nail head standoff<br />

of completed fastenings<br />

4.24 11 / 2007