X-M6, X-W6, X-F7, X-M8,<br />

X-M10, X-W10<br />

Corrosion information<br />

The intended use only comprises fastenings which are not directly exposed to external<br />

weather conditions or moist atmospheres. For further detailed information on corrosion see<br />

corresponding chapter in section Direct Fastening Technology.<br />

Recommended setting range<br />

No general restrictions existent. Limitations are depending on application and user requirements<br />

Fastener selection and system recommendation<br />

Fastener selection<br />

Required thread length<br />

Lg ≥ tl + twaher + tnut [mm]<br />

Shank length Ls [mm] 1 ):<br />

Fastener Normal weight concrete Light weight concrete<br />

X-M6/W6/F7 fc [N/mm2 ] 15 25 ≥ 35 15 25 ≥ 35<br />

Ls [mm] 32, 42 27 17, 22 42 32, 42 32<br />

X-M8, X-M10, X-W10 fc [N/mm2 15 25 ≥ 35 15 25 ≥ 35<br />

Ls [mm] 42 27, 32 27 42 42 42<br />

1 ) Note: For preliminary selection only, optimize by on-site trails to maximize pullout strength and minimize<br />

placing failures/spalls.<br />