Application requirements<br />

Thickness of base material<br />

Concrete<br />

X-U: hmin = 80 mm<br />

X-GHP, X-GN: hmin = 60 mm<br />

Recommended setting range<br />

Concrete<br />

No general restrictions existent. Limitations<br />

are depending on application and user<br />

requirements.<br />

Steel<br />

tI ≥ 4 mm<br />

Spacing and edge distances<br />

Spacing and edge distances depending on job site requirements.<br />

X-HSMX, X-CCMX<br />

Corrosion information<br />

These zinc coated fasteners are not suitable for long-term service outdoors or in otherwise<br />

corrosive environments.<br />

For further detailed information on corrosion see corresponding chapter in section Direct<br />

Fastening Technology.<br />

Steel<br />

For X-U and X-EDNI nail, see corresponding<br />

chapter<br />

X-EGN 14<br />

11 / 2007 4.185<br />

Steel thickness, tII [mm]<br />

20<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

400<br />

S235Jxx<br />

S275Jxx<br />

tII<br />

S355Jxx<br />

450 500 550 600 650 700 750<br />

Steel strength, Rm [N/mm2] Working beyond the recommended application range will lead to an increase of the failure rate.