X-FCP<br />

Load data<br />

Design data<br />

Recommended loads:<br />

Nrec = 1.8 [kN]<br />

Test data<br />

For test data please see corresponding pages for X-CRM threaded studs.<br />

Application requirements<br />

Thickness of base material<br />

X-CRM8<br />

tII<br />

Minimum steel thickness tII ≥ 6 mm<br />

Spacing and edge distances<br />

X-CR M8<br />

Edge distances: c ≥ 15 mm<br />

Spacing: s ≥ 15 mm<br />

c c s s<br />

Conditions:<br />

• Limited by the strength of the X-CRM8 threaded<br />

stud.<br />

• Recommended loads are valid for fastenings of steel<br />

and aluminum with 20 mm pre-drilling.<br />

• X-FCP-F and X-FCP-R are not intended for shear<br />

loading.<br />

Thickness of fastened material<br />

Thickness of checker plates: tI ≅ 5.0–13.0 mm<br />

Corrosion information<br />

The intended use of standard carbon steel fasteners only comprises fastenings which are not<br />

directly exposed to external weather conditions or moist atmospheres. For out-door applications<br />

stainless steel fasteners have to be used, see fastener selection. Further detailed information<br />

on corrosion see corresponding chapter in section Direct Fastening Technology.<br />