X-U<br />

Recommended setting range<br />

Fastening to steel<br />

Fastening of steel sheets and steel parts to steel Fastening of wood and soft material to steel<br />

Steel thickness, tII [mm]<br />

Fastener selection and system recommendation<br />

Fastening to concrete<br />

tI<br />

hET<br />

22<br />

20<br />

18<br />

16<br />

14<br />

12<br />

10<br />

S 235<br />

8<br />

S 275<br />

6<br />

S 355<br />

350 400 450 500 550 600 650<br />

Steel strength, Rm [N/mm2 ]<br />

X-U 16 P8: For steel sheeting with 0.75 mm<br />

≤ tI ≤ 1.25 mm sheets<br />

tI<br />

tII hET<br />

tI<br />

hET<br />

Required nail shank length: LS = hET + tl [mm]<br />

Recommendation: hET = 22 mm<br />

In case flush fastenings are required: LS = hET + tl – 5 [mm]<br />

Fastening to steel<br />

Fastening steel to steel Fastening wood to steel<br />

tII hET<br />

Required nail shank length: LS = hET + tl [mm]<br />

Recommendation: hET = 12 ± 2 mm<br />

4<br />

15 20 25 30 35 40 45 50 55<br />

Wood thickness, tI [mm]<br />

4.90 11 / 2007<br />

Steel thickness, tII [mm]<br />

9<br />

8<br />

7<br />

6<br />

5<br />

S 235 / 510 N/mm 2<br />

S 355 / 630 N/mm 2<br />

tI<br />

hET<br />

tI tI<br />

tII<br />

hET