04.11.2012 Views

0 Contents - Hilti Svenska AB

0 Contents - Hilti Svenska AB

0 Contents - Hilti Svenska AB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Recommended setting range<br />

Concrete: fcc = 15–45 N/mm 2<br />

Fastener selection and system recommendation<br />

Fastener selection<br />

aggregate size ≤ 32 mm<br />

Sand-lime masonry: fcc = 15–45 N/mm 2<br />

Clinker brick work: fcc = 28–45 N/mm 2<br />

Steel: fu = 360–540 N/mm 2<br />

tI<br />

Select L = tI<br />

For intermediate thicknesses, use<br />

next shorter X-IE.<br />

Use extension plate HDT 90 /<br />

HDT 90 BK for soft insulation.<br />

LS<br />

L<br />

tll = 4–6 mm<br />

o 60<br />

System recommendation<br />

Tool<br />

DX 460 IE<br />

Cartridge selection and tool energy setting<br />

11 / 2007 4.167<br />

X-IE<br />

Designation Fastener Item no. Ls [mm] L [mm]<br />

X-IE 6-25 PH 47 283990 47 25<br />

X-IE 6-30 PH 52 283991 52 30<br />

X-IE 6-35 PH 52 283992 52 35<br />

X-IE 6-40 PH 52 376466 52 40<br />

X-IE 6-45 PH 52 376467 52 40<br />

X-IE 6-50 PH 52 376468 52 40<br />

X-IE 6-60 PH 52 376469 52 40<br />

X-IE 6-70 PH 52 376470 52 40<br />

X-IE 6-75 PH 52 376471 52 40<br />

X-IE 6-80 PH 52 376472 52 80<br />

X-IE 6-90 PH 52 376473 52 90<br />

X-IE 6-100 PH 52 376474 52 100<br />

X-IE 6-120 PH 72 376475 72 120<br />

X-IE 6-140 PH 72 283339 72 140<br />

Cartridge recommendation: Steel: 6.8/11M red cartridge<br />

Concrete 6.8/11M yellow or red cartridge<br />

Masonry:<br />

Tool energy adjustment by setting tests on site.<br />

6.8/11M yellow or green cartridge