X-IE<br />

Load data<br />

Design data<br />

Recommended loads<br />

Insulation thickness tI [mm]<br />

X-IE 6 Shear, Vrec [N]<br />

40 45 50 60 70 75 80 100 120 140<br />

Polystyrol [15 kg/m 3 ] 150 200 250 300 300 325 350 350 350 350<br />

Styrofoam [15 kg/m 3 ] 600 600 600 600 600 600 600 600 600 600<br />

Pullover, Nrec [N]<br />

Polystyrol [15 kg/m 3 ] 250 270 290 300 300 300 300 300 300 300<br />

Styrofoam [15 kg/m 3 ] 300 300 300 300 300 300 300 300 300 300<br />

HDT 90 Pullover, Nrec [N]<br />

Mineral wool [ ≥ 7.5 kN/m 2 ]* – – – 135 135 135 135 135 135 135<br />

Mineral wool [ ≥ 15 kN/m 2 ]* – – – 250 250 250 250 250 250 250<br />

*) Tensile Strength σmt according to DIN EN 1607<br />

When base material properties are questionable, jobsite qualification a necessary<br />

N<br />

V<br />

Test data<br />

For more detailed information on the performance of the system please inquire at <strong>Hilti</strong>.<br />

Application requirements<br />

Thickness of base material<br />

Concrete: hmin = 80 mm<br />

Steel: tll ≥ 4 mm<br />

Thickness of fastened material<br />

Insulation thickness: tl = 25–140 mm<br />

Spacing and edge distances<br />

For setting instructions please inquire at the insulation material supplier.<br />

Corrosion information<br />

Corrosion information see X-IFV / SX-FV Approvals<br />