Fastening metal profiles<br />

Required nail shank length:<br />

Wood LS = hET + tl [mm]<br />

Required depth of penetration hET<br />

Normal weight concrete<br />

hET according to concrete strength fcc<br />

fcc [N/mm 2 ] < 25 > 25<br />

hET [mm] 42 37<br />

System recommendation<br />

Fasteners Tool 1 )<br />

Designation Item no. LS [mm] dnom [mm] Designation<br />

DS 27 P10 46157 27 4.5 DX 460, DX 76<br />

DS 32 P10 46158 32 4.5 DX 460, DX 76<br />

DS 37 P10 46159 37 4.5 DX 460, DX 76<br />

DS 42 P10 46160 42 4.5 DX 460, DX 76<br />

DS 47 P10 46161 47 4.5 DX 460, DX 76<br />

DS 52 P10 46162 52 4.5 DX 460, DX 76<br />

DSH 57 P10 40591 57 4.5 DX 460, DX 76<br />

DS 62 P10 46164 62 4.5 DX 460, DX 76<br />

DS 72 P10 46165 72 4.5 DX 460, DX 76<br />

1 ) Nail length limits are for use without pre-driving into the wood. Hand-driving the nail into<br />

the wood and bringing the DX tool into position over the nail head extend the nail length<br />

range for the tools.<br />

Cartridge selection and tool energy setting<br />

Cartridge recommendation: DX 460<br />

Steel: 6.8/11M red cartridge<br />

Concrete: 6.8/11M yellow or red cartridge<br />

Masonry: 6.8/11M green cartridge<br />

Cartridge recommendation: DX 76<br />

Steel: 6.8/18M red or black cartridge<br />

Concrete: 6.8/11M yellow or red cartridge<br />

Tool energy adjustment by setting tests on site.<br />

11 / 2007 4.139<br />