Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DS<br />

Recommended setting range<br />

Concrete Steel<br />

No general restrictions existent. Limitations 67<br />

are depending on application and user<br />

62<br />

requirements.<br />

57<br />

52<br />

47<br />

42<br />

37<br />

32<br />

Working beyond the recommended applica-<br />

27<br />

tion range will lead to an increase of the fail-<br />

6<br />

ure rate.<br />

Fastener selection<br />

Fastening wood or soft material<br />

Required nail shank length:<br />

Wood LS = hET + tl [mm]<br />

Soft material LS = hET + tl – 2 – hcs [mm]<br />

hCS ≅ 3 mm if possible<br />

Required depth of penetration hET<br />

Normal weight concrete<br />

Select hET according to fc<br />

fc [N/mm 2 ] 15 25 35<br />

hET [mm] 42 37 32<br />

Steel<br />

hET<br />

17–27 mm<br />

Steel thickness, tII [mm]<br />

4.138 11 / 2007<br />

Shank length, Ls [mm]<br />

t I<br />

h ET<br />

t I<br />

h ET<br />

DS<br />

8 10 12 14<br />

h CS<br />

t I<br />

h ET