X-IE<br />

Fastening quality assurance<br />

Fastening inspection<br />

L<br />

x<br />

tI<br />

Recognition of placing failures Visual check immediately after fastening<br />

Fastener rebounds Fastener remains on<br />

tool*<br />

Installation<br />

hET<br />

*) XI-FV and SX-FV with<br />

placing failure indication<br />

Insulation thickness tI [mm]<br />

40 45 50 60 70 75 80 100 120 140<br />

Concrete hET = 25–29 mm<br />

xmin [mm] 10 15 20 30 40 45 50 70 70 90<br />

xmax [mm] 14 19 24 34 44 49 54 74 74 94<br />

Steel and sand-lime hET = 20–24 mm<br />

xmin [mm] 5 10 15 25 35 40 45 65 65 85<br />

xmax [mm] 9 14 19 29 39 44 49 69 69 89<br />

Correct:<br />

Top hat crushed<br />

1. Load X-IE on cycled tool 2. Push the X-IE all the way<br />

into the insulation<br />

Incorrect:<br />

Top hat not crushed<br />

3. Pull the trigger to fasten<br />

4.168 11 / 2007