Installation Notes - USP Connectors
Installation Notes - USP Connectors
Installation Notes - USP Connectors
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
UNDERSADDLE HANGERS – TUS & DTUS SERIES<br />
TUS – For a single ply purlin.<br />
DTUS – For a single ply purlin with a 2-ply saddle dimension.<br />
Uplift<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Materials: 20 gauge<br />
Finish: G90 galvanizing<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Attachs with standard 11/2˝ joist hanger nails that can be<br />
installed with a positive placement nail gun or be<br />
hand driven.<br />
• Other 1-1/2˝ fasteners with a shear value equal or greater<br />
than a 10d nail may be used.<br />
NEW<br />
Typical TUS24<br />
installation<br />
F2<br />
F2<br />
Typical DTUS24<br />
installation<br />
Bottom<br />
View<br />
H<br />
H<br />
W<br />
TUS24S<br />
W<br />
3¼"<br />
DTUS24<br />
W<br />
H<br />
W<br />
TUS24<br />
W<br />
Joist Size<br />
2 x 4 - 6<br />
<br />
2 x 4 - 6<br />
saddle<br />
2 x 4 - 6<br />
saddle<br />
<strong>USP</strong><br />
Stock No.<br />
TUS24S<br />
TUS24<br />
DTUS24<br />
Dimensions (in)<br />
Fastener Schedule 2,3 Factored Resistance 1<br />
Header<br />
Joist<br />
DF-L (Lbs)<br />
S-P-F (Lbs)<br />
Steel<br />
Qty<br />
Qty<br />
Download Uplift 1 F2 Download Uplift 1 F2<br />
Ref. No. Gauge W H Face Bottom Type Face Bottom Type Unit 100% 115% 115% 100% 115% 115%<br />
-- --<br />
-- --<br />
-- --<br />
20<br />
20<br />
20<br />
1-9/16<br />
1-9/16<br />
1-9/16<br />
3<br />
3<br />
3<br />
4<br />
4<br />
4<br />
1<br />
1<br />
1<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
4<br />
4<br />
4<br />
1<br />
1<br />
1<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
8d x 1-1/2<br />
10d x 1-1/2<br />
LL915<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
Lbs<br />
980<br />
980<br />
980<br />
980<br />
980<br />
980<br />
980<br />
980<br />
980<br />
955<br />
955<br />
955<br />
955<br />
955<br />
955<br />
955<br />
955<br />
955<br />
385<br />
385<br />
385<br />
1120<br />
1120<br />
1120<br />
1120<br />
1120<br />
1120<br />
695<br />
695<br />
695<br />
695<br />
695<br />
695<br />
695<br />
695<br />
695<br />
680<br />
680<br />
680<br />
680<br />
680<br />
680<br />
680<br />
680<br />
680<br />
275<br />
275<br />
275<br />
795<br />
795<br />
795<br />
795<br />
795<br />
795<br />
kN<br />
kN<br />
kN<br />
kN<br />
kN<br />
kN<br />
kN<br />
kN<br />
kN<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.36<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
4.25<br />
1.71<br />
1.71<br />
1.71<br />
4.98<br />
4.98<br />
4.98<br />
4.98<br />
4.98<br />
4.98<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.09<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
3.02<br />
1.22<br />
1.22<br />
1.22<br />
3.54<br />
3.54<br />
3.54<br />
3.54<br />
3.54<br />
3.54<br />
1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
3) NAILS:<br />
red font.<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com 111<br />
<strong>USP</strong>2240-131<br />
Hangers