Masonry Uplift <strong>Connectors</strong> – SHA series<br />

Connects trusses directly to masonry or concrete and features slotted<br />

base holes to ease installation.<br />

Materials: Angle – 3 gauge; Gussets – 10 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Uplift<br />

F 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>Installation</strong>:<br />

• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />

• Bolts must be ordered seperately.<br />

• Install directly flush to masonry wall.<br />

• The SHA series connectors shall be installed in pairs.<br />

• Moisture barrier may be required.<br />

NEW<br />

Typical SHA6<br />

installation<br />

1 1 /2˝<br />

6˝<br />

3 1 /4˝<br />

4 1 /4˝<br />

2 1 /4˝<br />

Typical SHA6T<br />

installation<br />

1 1 /2˝<br />

6˝<br />

13 3 /4˝<br />

12 3 /4˝<br />

2 1 /2˝<br />

Truss & Rafter<br />

2 1 /4˝<br />

2 1 /2˝<br />

SHA6<br />

SHA6T<br />

Fastener Schedule 3 Factored Resistance (Lbs.) 1,2<br />

<strong>USP</strong><br />

Stock No.<br />

Concrete Wall Rafter/Truss 7<br />

Anchor Bolts 4,5,8<br />

No.<br />

Ref. No. Qty Dia. Qty Dia. of Plies 6 Unit<br />

SHA6 4 1/2 2 3/4<br />

SHA6T 4 1/2 2 3/4<br />

2 Ply<br />

3 Ply or ><br />

2 Ply<br />

3 Ply or ><br />

1) Factored resistances have been increased 15% for wind or seismic loads;<br />

no further increase shall be permitted.<br />

2) Factored resistances are for a pair of SHA devices. SHA's shall be installed in pairs.<br />

3) Fastener schedule is for a pair of SHA devices.<br />

<br />

5) Concrete compressive strength shall be 2500 psi or greater at 28 days.<br />

6) Multiple ply truss shall be fastened together to act as a single unit.<br />

<br />

<br />

New products or updated product information are designated in red font.<br />

DF-L<br />

Uplift<br />

S-P-F<br />

Uplift<br />

115% 115%<br />

Lbs 2500 2500<br />

kN 11.12 11.12<br />

Lbs 3750 3750<br />

kN 16.68 16.68<br />

Lbs 11180 8825<br />

kN 49.73 39.26<br />

Lbs 12600 8945<br />

kN 56.05 39.79<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 157<br />