Installation Notes - USP Connectors
Installation Notes - USP Connectors
Installation Notes - USP Connectors
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Moisture Barrier Plates – NOP series<br />
Moisture Barrier Plates protect the bottom chords<br />
of trusses from moisture damage caused by direct<br />
contact with concrete. These plates eliminate the<br />
need for more expensive treated wood plates.<br />
W<br />
L<br />
Truss & Rafter<br />
Materials: See chart<br />
Finish: G90 galvanizing<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>,<br />
page 10.<br />
• Pre-attach to truss bottom chord or rafter using<br />
prepunched prongs and/or 6d common nails to<br />
prevent wood-to-concrete contact.<br />
<strong>USP</strong><br />
Steel<br />
Dimensions Fastener Schedule 1,2<br />
Size Stock No. Ref. No. Gauge W L Qty Type<br />
NOP2X TSS2, TBP8 26 1-7/16 8 -- -- -- --<br />
2x<br />
NOP1 -- -- 22 1-1/2 8 2 6d<br />
4x NOP4 TSS2-2 26 3-1/2 8 2 6d<br />
1) Minimum nail embedment shall be 8 nail diameters (typ).<br />
2) NAILS<br />
W<br />
NOP1<br />
L<br />
NOP2X<br />
NOP4<br />
W<br />
Typical NOP4<br />
installation<br />
NOP4<br />
L<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Embedded Truss Anchors – LPTA<br />
Low profile design attaches to 2 x 4 or larger bottom chords and<br />
provides uplift and lateral load resistance.<br />
Materials: 18 gauge<br />
Finish: G90 galvanizing<br />
Codes: Load values are derived from data<br />
submitted to various North American<br />
building code evaluators.<br />
F 1<br />
Uplift<br />
F 2<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Embed LPTA 4˝ into concrete tie beam or masonry bond<br />
beam.<br />
• Anchors should be spaced no closer than 8˝ centre-to-centre.<br />
• Moisture barrier may be required.<br />
Typical LPTA installation<br />
W<br />
Dimensions (in)<br />
Fastener Schedule<br />
Factored Resistance (115%) 1<br />
<strong>USP</strong><br />
Steel<br />
Min<br />
DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />
Stock No. Ref. No. Gauge W H Qty 2 Type 3,4 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2<br />
LPTA LTA2 18 5 8-1/4 10 10d x 1-1/2 1555 1005 1865 6.92 4.47 8.30 1555 1005 1865 6.92 4.47 8.30<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other<br />
load durations in accordance with the code.<br />
2) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet<br />
published factored resistance of product.<br />
3) Minimum nail embedment shall be 8 nail diameters (typ).<br />
4) NAILS<br />
1 7 /16˝<br />
LPTA<br />
H<br />
1 3 /4˝<br />
152<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com