Elevated Post Bases - EBG, EPB & EPBH series<br />
These post bases allow installers to pre-align posts and pre-set post<br />
heights above concrete floors or footings. By eliminating<br />
post-to-concrete contact, moisture damage is reduced. Elevated<br />
post bases are ideal for building carports, decks or porches. All<br />
series feature convenient nail fastening to post.<br />
NEW<br />
SIZES<br />
1˝ Max.<br />
elevation<br />
Caps & Bases<br />
54<br />
Materials: EPB – 14 gauge tube; 12 gauge steel U-bracket<br />
EBG44 – 16 gauge tube; 16 gauge steel U-bracket<br />
EPBH – U-bracket – 12 gauge HRPO steel;<br />
Stem – 15 mm rebar<br />
Finish: EPB – <strong>USP</strong> primer; EBG44 – G-185 galvanizing;<br />
EPBH – Hot-dip galvanized<br />
Options: EPB4408, EPB4608, and EPB6608 are available<br />
in Hot-dip galvanized. To order, add HDG to stock<br />
number, as in EPB4408-HDG.<br />
Codes: Load values are derived from data submitted to<br />
various North American building code evaluators.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Not recommended for fence posts or other<br />
unrestrained (not fixed or fastened at top) applications. These<br />
anchors are not designed to resist overturning (moment) loads<br />
L<br />
Schedule 3,4<br />
DF-L<br />
S-P-F<br />
Post <strong>USP</strong><br />
Bearing F1 1,2 F2 1,2 Uplift 2 Bearing F1 1,2 F2 1,2 Uplift 2<br />
W<br />
<strong>USP</strong><br />
Dimensions (in) Fastener Schedule 1,2 6 3/8˝<br />
Size Stock No. Ref. No. W L H1 H2 Qty Type Unit 100% 115% 115% 115% 100% 115% 115% 115%<br />
4 x 4 EPBH44<br />
EPB44PHDG,<br />
RCPS3.5HDG<br />
3-1/2 3-3/8 2-3/4 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />
4 x 6<br />
Rough<br />
EPBH46R RCPS46HDG 4-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />
6 x 6 EPBH66 RCPS5.5HDG 5-1/2 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />
6 x 6<br />
Rough<br />
EPBH66R RCPS6HDG 6-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />
4 x 4 EPB4408<br />
EPB44,<br />
Lbs 3045 1115 1075 1140 2620 960 925 980<br />
3-9/16 3 3 8 8 16d<br />
EPB44-12<br />
kN 13.55 4.96 4.78 5.07 11.65 4.27 4.11 4.36<br />
H 2<br />
4 x 6 EPB4608<br />
EPB46,<br />
Lbs 3045 2270 1695 1560 2620 1950 1460 1340<br />
3-9/16 5 3 8 12 16d<br />
EPB46-12<br />
kN 13.55 10.10 7.54 6.94 11.65 8.67 6.49 5.96<br />
6 x 6 EPB6608<br />
EPB66,<br />
Lbs 4665 2270 1695 1560 4010 1950 1460 1340<br />
5-9/16 5 3-3/16 8 12 16d<br />
EPB66-12<br />
kN 20.75 10.10 7.54 6.94 17.84 8.67 6.49 5.96<br />
4 x 4 EBG44-TZ EPB44A 3-9/16 2-3/4 2-3/8 7-1/2 8 16d HDG<br />
Lbs 2485 1100 1180 1085 2135 945 1015 935<br />
kN 11.05 4.89 5.25 4.83 9.50 4.20 4.52 4.16<br />
1) Lateral loads (F1 and F2) are for conditions where pipe extends no more than 1" above the concrete surface.<br />
2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for<br />
other load durations in accordance with the code.<br />
3) Minimum nail embedment shall be 8 nail diameters (typ).<br />
4) NAILS:<br />
New products or updated product information are designated in red font.<br />
Height Adjustable Post Base – APB Series<br />
W L<br />
H 1<br />
H 2<br />
Post Size Stock No. Ref. No. W L H1 H2 Qty Type<br />
4 x 4 APB44 -- -- 3-1/2 3-3/8 2-3/4 6-3/4 4 16d HDG<br />
6 x 6 APB66 -- -- 5-1/2 5-3/8 2-7/8 6-3/4 4 16d HDG<br />
1) Minimum nail embedment shall be 8 nail diameters (typ).<br />
2) NAILS:<br />
Dimensions (in) Fastener<br />
Factored Resistance (115%) 2<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />
Typical EPBH<br />
installation<br />
H 1<br />
H 2<br />
W<br />
L<br />
EPBH<br />
Allows height adjustments of post after installation. A maximum height adjustment of 4˝ can be achieved<br />
with this product. Adjustments may be required if original installation is not exact, if there is a greater slope<br />
on a deck than estimated, or if there is heaving or sinking of the post beyond the initial installation. Embed<br />
in concrete a minimum of 6˝. Useful for reducing moisture damage.<br />
Materials: 16 gauge tube; 12 gauge steel U-bracket<br />
Finish: Hot-dip galvanized<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Not recommended for fence posts or other unrestrained<br />
(not fixed or fastened at top) applications. These anchors are not<br />
designed to resist overturning (moment) loads<br />
APB<br />
Typical EBG44-TZ<br />
installation<br />
F 2<br />
F 1<br />
Uplift<br />
EPB/EBG<br />
similar<br />
Typical APB<br />
installation<br />
Bearing<br />
Typical EPB<br />
installation<br />
H 1<br />
3" Min.<br />
edge<br />
distance<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®