Elevated Post Bases - EBG, EPB & EPBH series<br />

These post bases allow installers to pre-align posts and pre-set post<br />

heights above concrete floors or footings. By eliminating<br />

post-to-concrete contact, moisture damage is reduced. Elevated<br />

post bases are ideal for building carports, decks or porches. All<br />

series feature convenient nail fastening to post.<br />

NEW<br />

SIZES<br />

1˝ Max.<br />

elevation<br />

Caps & Bases<br />

54<br />

Materials: EPB – 14 gauge tube; 12 gauge steel U-bracket<br />

EBG44 – 16 gauge tube; 16 gauge steel U-bracket<br />

EPBH – U-bracket – 12 gauge HRPO steel;<br />

Stem – 15 mm rebar<br />

Finish: EPB – <strong>USP</strong> primer; EBG44 – G-185 galvanizing;<br />

EPBH – Hot-dip galvanized<br />

Options: EPB4408, EPB4608, and EPB6608 are available<br />

in Hot-dip galvanized. To order, add HDG to stock<br />

number, as in EPB4408-HDG.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

<strong>Installation</strong>:<br />

• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />

• Not recommended for fence posts or other<br />

unrestrained (not fixed or fastened at top) applications. These<br />

anchors are not designed to resist overturning (moment) loads<br />

L<br />

Schedule 3,4<br />

DF-L<br />

S-P-F<br />

Post <strong>USP</strong><br />

Bearing F1 1,2 F2 1,2 Uplift 2 Bearing F1 1,2 F2 1,2 Uplift 2<br />

W<br />

<strong>USP</strong><br />

Dimensions (in) Fastener Schedule 1,2 6 3/8˝<br />

Size Stock No. Ref. No. W L H1 H2 Qty Type Unit 100% 115% 115% 115% 100% 115% 115% 115%<br />

4 x 4 EPBH44<br />

EPB44PHDG,<br />

RCPS3.5HDG<br />

3-1/2 3-3/8 2-3/4 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 6<br />

Rough<br />

EPBH46R RCPS46HDG 4-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

6 x 6 EPBH66 RCPS5.5HDG 5-1/2 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

6 x 6<br />

Rough<br />

EPBH66R RCPS6HDG 6-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 4 EPB4408<br />

EPB44,<br />

Lbs 3045 1115 1075 1140 2620 960 925 980<br />

3-9/16 3 3 8 8 16d<br />

EPB44-12<br />

kN 13.55 4.96 4.78 5.07 11.65 4.27 4.11 4.36<br />

H 2<br />

4 x 6 EPB4608<br />

EPB46,<br />

Lbs 3045 2270 1695 1560 2620 1950 1460 1340<br />

3-9/16 5 3 8 12 16d<br />

EPB46-12<br />

kN 13.55 10.10 7.54 6.94 11.65 8.67 6.49 5.96<br />

6 x 6 EPB6608<br />

EPB66,<br />

Lbs 4665 2270 1695 1560 4010 1950 1460 1340<br />

5-9/16 5 3-3/16 8 12 16d<br />

EPB66-12<br />

kN 20.75 10.10 7.54 6.94 17.84 8.67 6.49 5.96<br />

4 x 4 EBG44-TZ EPB44A 3-9/16 2-3/4 2-3/8 7-1/2 8 16d HDG<br />

Lbs 2485 1100 1180 1085 2135 945 1015 935<br />

kN 11.05 4.89 5.25 4.83 9.50 4.20 4.52 4.16<br />

1) Lateral loads (F1 and F2) are for conditions where pipe extends no more than 1" above the concrete surface.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for<br />

other load durations in accordance with the code.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

Height Adjustable Post Base – APB Series<br />

W L<br />

H 1<br />

H 2<br />

Post Size Stock No. Ref. No. W L H1 H2 Qty Type<br />

4 x 4 APB44 -- -- 3-1/2 3-3/8 2-3/4 6-3/4 4 16d HDG<br />

6 x 6 APB66 -- -- 5-1/2 5-3/8 2-7/8 6-3/4 4 16d HDG<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

Dimensions (in) Fastener<br />

Factored Resistance (115%) 2<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Typical EPBH<br />

installation<br />

H 1<br />

H 2<br />

W<br />

L<br />

EPBH<br />

Allows height adjustments of post after installation. A maximum height adjustment of 4˝ can be achieved<br />

with this product. Adjustments may be required if original installation is not exact, if there is a greater slope<br />

on a deck than estimated, or if there is heaving or sinking of the post beyond the initial installation. Embed<br />

in concrete a minimum of 6˝. Useful for reducing moisture damage.<br />

Materials: 16 gauge tube; 12 gauge steel U-bracket<br />

Finish: Hot-dip galvanized<br />

<strong>Installation</strong>:<br />

• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />

• Not recommended for fence posts or other unrestrained<br />

(not fixed or fastened at top) applications. These anchors are not<br />

designed to resist overturning (moment) loads<br />

APB<br />

Typical EBG44-TZ<br />

installation<br />

F 2<br />

F 1<br />

Uplift<br />

EPB/EBG<br />

similar<br />

Typical APB<br />

installation<br />

Bearing<br />

Typical EPB<br />

installation<br />

H 1<br />

3" Min.<br />

edge<br />

distance<br />