Roof Boundary Clip – RBC<br />
Framing plate designed to connect roof<br />
blocking to a wall top plate.<br />
Materials: 20 gauge<br />
Finish: G90 galvanizing<br />
Codes: Load values are derived<br />
from data submitted to<br />
various North American<br />
building code evaluators.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners.See<br />
Product <strong>Notes</strong>, page 10.<br />
• Field adjustable from 0º to 90º.<br />
• Bend angle only once.<br />
Typical RBC<br />
Top-Plate to Outside of Blocking<br />
installation<br />
Typical RBC<br />
Top-Plate to Inside of Blocking<br />
installation<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Typical RBC<br />
Concrete Blockwall to Blocking<br />
installation<br />
Typical RBC<br />
1˝ foamboard installation<br />
H<br />
W<br />
Angles & Straps<br />
RBC<br />
Dimensions (in)<br />
Fastener Schedule 2,3,4<br />
Factored Resistance 1<br />
Top Plate Blocking<br />
F1 (115%)<br />
DF-L S-P-F<br />
<strong>USP</strong><br />
Steel<br />
<strong>Installation</strong><br />
Stock No. Ref. No. Gauge W H Type Qty Type 2 Qty Type 2 Lbs kN Lbs kN<br />
Wood to Wood 6 10d x 1-1/2 6 10d x 1-1/2 990 4.40 615 2.74<br />
RBC RBC 20 4-1/4 6<br />
Wood to CMU 3 1/4" Tapcon 6 10d x 1-1/2 735 3.27 525 2.34<br />
1) Loads shown are for a single roof boundary clip.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
<br />
4) NAILS: 10d x 1-1/2 nails are 0.148" diameter by 1-1/2" long.<br />
New products or updated product information are designated in red font.<br />
68<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com