Foundation Anchors – FA3 series<br />

Concrete & Masonry<br />

For installation into concrete slabs. The FA3 features a split flange for nailing<br />

to both mudsill and stud for greater framing versatility.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Options: FA3 is available in Triple Zinc.<br />

To order, add TZ to end of stock number,<br />

as in FA3-TZ.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code<br />

evaluators.<br />

<strong>Installation</strong>:<br />

• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />

• Use a minimum of two anchors per mudsill. An anchor should always be<br />

within 12˝ of the end of each mudsill section.<br />

• Do not rely on these anchors to secure concrete sections together between<br />

cold joints.<br />

• Insert into wet concrete (minimum strength of 2,000 psi). Place mudsill after<br />

concrete cures. Secure flanges to sill (and stud, if applicable), bending flanges<br />

as needed to achieve a tight fit. Fasten as directed in chart.<br />

1 1 /2˝<br />

4 5 /8˝<br />

F2<br />

5 3 /4˝<br />

FA3<br />

F1<br />

Embossed lines<br />

provide guide for<br />

matching to edge<br />

of form board<br />

1˝<br />

Uplift<br />

Typical FA3 installation<br />

in concrete<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

FA3 Form board<br />

installation<br />

Alternate FA3<br />

installation<br />

Typical FA3 installation<br />

to mudsill and stud<br />

Plate<br />

Size<br />

2 x4<br />

or<br />

2 x 6<br />

2 x4<br />

or<br />

2 x 6<br />

Dimensions (in)<br />

Fastener Schedule 1,9 DF-L Factored Resistance 2,3,5,6,7<br />

S-P-F Factored Resistance 2,3,5,6,7<br />

Sill Plate<br />

Stud Min Wind and SDC A & B SDC C-F Wind and SDC A & B SDC C-F<br />

Stemwall<br />

Side Top Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2<br />

<strong>USP</strong> Ref. Steel<br />

Thickness<br />

Stock No No. Ga. W L I E D Qty Qty Type Qty Type (in.) Unit 115% 115% 115% 115% 115% 115% 115% 115% 115% 115% 115% 115%<br />

Uncracked Concrete 8<br />

FA3<br />

Lbs 1045 645 760 1045 645 760 900 555 655 900 555 655 1010 62<br />

2 4 10d x 1-1/2 -- -- -- -- 6<br />

Mudsill Only MAS<br />

kN 4.65 2.87 3.38 4.65 2.87 3.38 4.00 2.47 2.91 4.00 2.47 2.91<br />

16 1-1/2 4-5/8 4 1<br />

FA3<br />

Lbs 780 635 480 780 635 480 670 545 415 670 545 415 755 61<br />

2 2 10d x 1-1/2 2 10d x 1-1/2 6<br />

Mudsill & Stud<br />

kN 3.47 2.82 2.14 3.47 2.82 2.14 2.98 2.42 1.85 2.98 2.42 1.85<br />

Cracked Concrete 8<br />

FA3<br />

Lbs 1020 565 760 875 485 670 875 485 655 755 415 575 985 54<br />

2 4 10d x 1-1/2 -- -- -- -- 6<br />

Mudsill Only MAS<br />

kN 4.54 2.51 3.38 3.89 2.16 2.98 3.89 2.16 2.91 3.36 1.85 2.56<br />

16 1-1/2 4-5/8 4 1<br />

FA3<br />

Lbs 780 565 480 780 485 480 670 485 415 670 415 415 755 54<br />

2 2 10d x 1-1/2 2 10d x 1-1/2 6<br />

Mudsill & Stud<br />

kN 3.47 2.51 2.14 3.47 2.16 2.14 2.98 2.16 1.85 2.98 1.85 1.85<br />

1) Predrilled holes are not required.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increased is allowed.<br />

3) FA3 capacities are based on using a single-ply 2x sill plate.<br />

4) Minimum distance of 1.5 x I E ( 6 inches) is required to obtain the listed capacity.<br />

5) Minimum anchor spacing for full capacity is 2 x l E . For spacing less than that reduce capacity proportionally.<br />

6) Factored resistances are based on lumber with a specific gravity of 0.49 and a moisture content of 19% or less.<br />

7) Uplift deformation based on wood connection strength.<br />

8) Minimum concrete strength f'c = 2500 psi<br />

9) Minimum nail embedment shall be 8 nail diameters (typ).<br />

10) NAILS:<br />

New products or updated product information are designated in red font.<br />