Girder Tiedowns – LUGT series<br />
Truss & Rafter<br />
The LUGT series is an extremely adaptable tiedown for girder trusses and offers several installation options to<br />
accommodate different framing conditions. It is an ideal retrofit solution to reinforce truss connections to transfer<br />
high wind loads to supporting walls and can be used on either wood framed, concrete or CMU block walls.<br />
LUGT1 – is designed for wood framed walls.<br />
LUGTC2 – is designed for corner hip trusses on wood framed walls.<br />
LUGT2, LUGT3 & LUGT4 – are designed for wood frame, concrete or CMU block walls.<br />
Materials: See chart<br />
Finish: G90 galvanizing<br />
Codes: Factored resistances are derived from data submitted to various North American building code<br />
evaluators and are in accordance with CSA O86-09.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• All nail holes must be filled with specified nails to achieve<br />
loads listed in the chart. Large holes are for concrete/<br />
masonry installations and do not need to be filled<br />
when used for girder-to-stud applications.<br />
• WS Wood Screws included with LUGT3 and LUGT4.<br />
• For concrete and masonry applications, a moisture<br />
barrier may be required, check local building code.<br />
Uplift<br />
F 1<br />
Uplift<br />
Typical LUGT2<br />
installation<br />
F 1<br />
Uplift<br />
NEW<br />
SIZES<br />
F2<br />
Typical LUGT3<br />
installation<br />
(LUGT4 similar)<br />
Uplift<br />
F1<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
F1 F2<br />
F2<br />
Typical LUGT1<br />
installation<br />
Typical LUGTC2<br />
installation<br />
F 2<br />
3 1/4˝<br />
Typical LUGT2<br />
masonry installation<br />
Typical LUGT4<br />
masonry installation<br />
(LUGT3 similar)<br />
3 3/16˝<br />
14 13/16˝<br />
12 7/8˝<br />
154<br />
<strong>USP</strong><br />
Stock No.<br />
LUGT1<br />
LUGTC2<br />
3"<br />
LUGT2<br />
LUGT3<br />
Fastener Schedule 3,7,8,9,10<br />
Factored Resistance (115%) 1,2<br />
No.<br />
S-P-F (Lbs)<br />
Steel of<br />
Rafter/Truss Plate<br />
Stud 4,5,6 DF-L (Lbs) DF-L (kN)<br />
S-P-F (kN)<br />
Ref. No. Gauge Plies Qty Type Qty Type Qty Type F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />
LUGT1 H10S 16 1 8 8d x 1-1/2 8 8d x 1-1/2 7 8d x 1-1/2 1045 495 1580 4.65 2.20 7.03 900 425 1455 4.00 1.89 6.47<br />
LUGT2 LGT2 14 2 16 10d 2 10d 14 10d 1050 455 2340 4.67 2.02 10.41 905 390 2010 4.03 1.73 8.94<br />
LUGTC2 -- -- 14 2 16 10d 2 10d 14 10d -- -- 595 2340 -- -- 2.65 10.41 -- -- 510 2010 -- -- 2.27 8.94<br />
LUGT3 LGT3-SDS2.5 12 3 12 WS25 4 16d Sinker 24 16d Sinker 3155 1415 6025 14.03 6.29 26.80 2705 1215 5945 12.03 5.4 26.45<br />
LUGT4 LGT4-SDS3 12 4 16 WS3 5 16d Sinker 32 16d Sinker -- -- -- -- 8340 -- -- -- -- 37.10 -- -- -- -- 7150 -- -- -- -- 31.81<br />
Concrete or Masonry Application<br />
LUGT2 LGT2 14 2 16 10d -- -- -- -- 5 1/4WB 1265 475 1915 5.63 2.11 8.52 1085 410 1645 4.83 1.82 7.32<br />
LUGT3 LGT3-SDS2.5 12 3 12 WS25 -- -- -- -- 4 3/8WB -- -- -- -- 5330 -- -- -- -- 23.71 -- -- -- -- 5260 -- -- -- -- 23.40<br />
LUGT4 LGT4-SDS3 12 4 16 WS3 -- -- -- -- 4 3/8WB -- -- -- -- 6185 -- -- -- -- 27.51 -- -- -- -- 5300 -- -- -- -- 23.58<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) Factored resistances apply where roof pitch is between 3:12 and 8:12.<br />
3) Additional anchorage products to be designed by others.<br />
4) 1/4WB denotes a 1/4" x 3" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.<br />
5) 3/8WB denotes a 3/8" x 5" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.<br />
6) Fasteners must be installed in fully grouted and reinforced concrete masonry (f'm = 1500 psi) or reinforced concrete (f'c = 2500 psi).<br />
7) Minimum nail embedment shall be 8 nail diameters (typ).<br />
8) For proper installation, the number of studs must be equal-to or greater-than the number of roof truss plies.<br />
9) Wedge Bolts are not supplied with the LUGT2, LUGT3 or LUGT4.<br />
10) NAILS: 8d x 1-1/2 are 0.131" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d Sinkers are 0.148" dia. x 3-1/4" long,<br />