Coiled Strapping – CMST series, CMSTC16, & RS series<br />
Angles & Straps<br />
76<br />
Coiled strapping enables cut-to-length convenience<br />
for a variety of immediate job site needs.<br />
CMST – 3˝ wide strapping features diamond nail<br />
holes to provide nailing options and reduce wood<br />
splitting.<br />
CMSTC – 3˝ wide strapping is designed for high load<br />
conditions. Engineered to reduce wood splitting.<br />
RS – 11⁄4˝ wide strapping packaged in cartons<br />
containing 25-foot or longer coils.<br />
Materials: See chart<br />
Finish: G90 galvanizing<br />
Options: RS150 is available in Triple Zinc. To<br />
order, add TZ to stock number, as<br />
in RS150-TZ.<br />
Codes: Load values are derived from data<br />
submitted to various North American<br />
building code evaluators.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>,<br />
page 10.<br />
• For safety, always wear gloves when handling or<br />
cutting coiled strapping.<br />
• CMST installations: Install to a minimum 2 ply 2x<br />
edge. Increase nail spacing if wood begins to split.<br />
• Designer may specify alternate nailing schedules. Refer<br />
to Nail Specification table on page 14 for nail shear<br />
values. Load values shall not exceed published factored<br />
resistance.<br />
Optional nails<br />
(wood shrinkage<br />
may occur and<br />
cause strap to<br />
buckle outward)<br />
Rim Joist <strong>Installation</strong> Fastener<br />
Factored Resistance<br />
Schedule 2,3,4,5<br />
Allowable Tension 1<br />
End<br />
Nail<br />
<strong>USP</strong><br />
Steel Coil<br />
Length<br />
Spacing DF-L (Lbs) DF-L (kN) SPF (Lbs) SPF (kN)<br />
Stock No. Ref. No. Gauge Length Cut Length (in) Qty Type O.C. 100% 115% 100% 115% 100% 115% 100% 115%<br />
CMSTC16 CMSTC16 16 54'<br />
21" <br />
56 10d<br />
42" <br />
7070 7070 31.45 31.45 6655 7070 29.60 31.45<br />
28" 64 16d 9945 9945 44.24 44.24 8960 9945 39.86 44.24<br />
CMST14 CMST14 14 52-1/2' 68" <br />
76 10d<br />
134" <br />
9945 9945 44.24 44.24 9030 9945 40.17 44.24<br />
40" 88 16d 13975 13975 62.17 62.17 12320 13975 54.80 62.17<br />
CMST12 CMST12 12 40' 92" <br />
104 10d<br />
184" <br />
13975 13975 62.17 62.17 12355 13975 54.96 62.17<br />
RS300<br />
RS250<br />
RS200<br />
RS100<br />
RS150<br />
RS14-100<br />
RS22-R<br />
RS20-R<br />
RS18-R<br />
RS16-R<br />
RS14-R<br />
CS22<br />
CS20<br />
CS18<br />
CS18S<br />
CS16<br />
CS14<br />
CS22-R<br />
CS20-R<br />
CS18-R<br />
CS16-R<br />
CS14-R<br />
22<br />
20<br />
18<br />
18<br />
16<br />
14<br />
22<br />
20<br />
18<br />
16<br />
14<br />
300'<br />
250'<br />
200'<br />
100'<br />
150'<br />
100'<br />
25'<br />
25'<br />
25'<br />
25'<br />
25'<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
6"<br />
7"<br />
8"<br />
8"<br />
9"<br />
12"<br />
6"<br />
7"<br />
8"<br />
9"<br />
12"<br />
16<br />
18<br />
20<br />
20<br />
24<br />
30<br />
16<br />
18<br />
20<br />
24<br />
30<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
10d<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
1390<br />
1595<br />
2010<br />
2010<br />
2645<br />
3565<br />
1390<br />
1595<br />
2010<br />
2645<br />
3565<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
6.18<br />
7.10<br />
8.94<br />
8.94<br />
11.77<br />
15.86<br />
6.18<br />
7.10<br />
8.94<br />
11.77<br />
15.86<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
7"<br />
8"<br />
9"<br />
9"<br />
11"<br />
15"<br />
7"<br />
8"<br />
9"<br />
11"<br />
15"<br />
18<br />
20<br />
24<br />
24<br />
28<br />
38<br />
18<br />
20<br />
24<br />
28<br />
38<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
8d<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
1295<br />
1500<br />
2010<br />
2010<br />
2610<br />
3605<br />
1295<br />
1500<br />
2010<br />
2610<br />
3605<br />
1415<br />
1595<br />
2100<br />
2100<br />
2645<br />
3920<br />
1415<br />
1595<br />
2100<br />
2645<br />
3920<br />
5.76<br />
6.67<br />
8.94<br />
8.94<br />
11.61<br />
16.04<br />
5.76<br />
6.67<br />
8.94<br />
11.61<br />
16.04<br />
6.29<br />
7.10<br />
9.34<br />
9.34<br />
11.77<br />
17.44<br />
6.29<br />
7.10<br />
9.34<br />
11.77<br />
17.44<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />
2) Fasteners to be installed with equal fasteners at each end of the connection.<br />
3) 16d sinker nails may be substituted for 10d nails with no load reduction.<br />
4) Minimum nail embedment shall be 8 nail diameters (typ).<br />
5) NAILS:<br />
red font.<br />
Typical RS<br />
rim joist installation<br />
CMST similar<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />
End<br />
Length<br />
Clear<br />
Span<br />
1˝ Min. End<br />
Length<br />
Cut<br />
Length<br />
1 1 /2˝<br />
3/4˝<br />
1 1 /2˝<br />
3˝ Typ.<br />
1 3 /4˝<br />
3 1 /2˝<br />
1 1 /4˝<br />
1/2˝<br />
RS<br />
3˝<br />
2 1 /4˝<br />
3/4˝<br />
CMSTC16<br />
3˝<br />
1 1 /2˝<br />
1˝<br />
CMST<br />
3/8˝<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®