Specialty Options & General <strong>Notes</strong><br />

Specialty Options<br />

<strong>USP</strong><br />

Series<br />

Width<br />

Skewed (Maximum)<br />

Sloped Seat (Maximum)<br />

Sloped / Skewed<br />

Sloped Top Flange (Maximum)<br />

BPH all 50º 45º 45º <br />

GHF all 50º 45º <br />

67-1/2º<br />

HD 1<br />

45º<br />

50º<br />

67-1/2º<br />

HDO 45º<br />

50º<br />

Top Flange Offset<br />

Saddle Hanger<br />

Ridge Hanger (Maximum)<br />

Inverted Flange<br />

<br />

width ><br />

<br />

width ><br />

<br />

width ><br />

Uplift<br />

Weldability<br />

<strong>USP</strong> Series<br />

Catalog Page Reference<br />

124-125,<br />

128-129,<br />

132-136,<br />

138-142<br />

146<br />

90-96,<br />

<br />

118,<br />

122-123<br />

97,<br />

<br />

99-101<br />

HGU all 45º<br />

<br />

145<br />

width ><br />

HJC all 60º 173<br />

126,<br />

HLBH all 50º 45º 45º 45º 132-136,<br />

138-142<br />

<br />

89,<br />

HUS<br />

all<br />

width ><br />

91-95,<br />

<br />

119, 123,<br />

167<br />

HWUH all 45º 45º 106-107<br />

KB all <br />

97,<br />

100-101<br />

KEG all 45º 45º 147<br />

KGB all 148<br />

KGLS all 50º 45º 30º 150<br />

KGLST all 150<br />

KGLT all 50º 45º 45º 149<br />

KHGB all 148<br />

KHGLS all 50º 45º 30º 150<br />

KHGLST all 150<br />

KHGLT all 50º 45º 45º 149<br />

KHHB all 148<br />

KHW all 84º 45º 35º 45º <br />

98,<br />

100-101<br />

KLB all 97, 99<br />

KLEG all 45º 45º 147<br />

KMEG all 45º 45º 147<br />

LGU all 45º<br />

<br />

145<br />

width ><br />

LSSH all 45º 45º 103, 144<br />

MGU all 45º<br />

<br />

145<br />

width ><br />

MPH 1 60º 45º <br />

108,<br />

126-141<br />

MSHL/R all 45º 170<br />

PHM 1 all 84º 45º 35º 45º <br />

126-131,<br />

133-141<br />

PHXU 1 all 60º 45º 35º <br />

126-129,<br />

132-136,<br />

138-142<br />

SKH all 45º 104-105<br />

SKHH all 45º 104-105<br />

SUH<br />

67-1/2º<br />

88,<br />

45º <br />

<br />

50º<br />

91-96<br />

SW 1 all 84º 45º 35º 45º 98-100<br />

SWH 1 all 84º 45º 35º 45º 98-101<br />

THD all<br />

45º 45º <br />

<br />

<br />

<br />

<br />

width ><br />

<br />

120, 123,<br />

165<br />

The information listed only applies<br />

to hangers manufactured by<br />

<strong>USP</strong> Structural <strong>Connectors</strong>® and<br />

installed according to the<br />

instructions listed in this catalogue.<br />

Some of the options listed may not<br />

have been evaluated on a single<br />

hanger. The designer must always<br />

evaluate each connection, including<br />

the joist and header capacities,<br />

before specifying a specialty<br />

connector. <strong>USP</strong> sloped hangers are<br />

manufactured with the plumb cut of<br />

the joist already calculated. If a<br />

hanger with a different height is<br />

needed, it must be specified at the<br />

time of ordering.<br />

Materials: Steel gauge may vary<br />

from that specified depending on<br />

the specialty option and<br />

manufacturing process used. Some<br />

formed hangers may be welded<br />

when modifying the hanger. Hanger<br />

configurations, fastener schedules,<br />

and height may vary from the tables<br />

depending on the joist size, skew,<br />

and slope.<br />

Finish: See specific hanger option<br />

tables. Welded hangers are painted<br />

with <strong>USP</strong> gray primer. Custom<br />

hangers available in Hot-dip<br />

galvanized, use HDG after product<br />

number.<br />

Factored Resistance: For multiple<br />

options for the same connector, use<br />

the most conservative reduction to<br />

give the lowest design load.<br />

<strong>Installation</strong>:<br />

• Fill all nail holes with fasteners<br />

specified in the tables.<br />

• Fastener quantities may increase<br />

from the amount listed in the tables<br />

depending on hanger option.<br />

• NA16D-RS and NA20D nails are<br />

supplied with hangers.<br />

• For type A skewed hangers, the<br />

end of joist must be bevel cut; for<br />

type B skewed hangers, the end of<br />

joist must be butt-cut.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

THDH all 45º 45º <br />

THF<br />

67-1/2º<br />

50º<br />

45º <br />

<br />

width ><br />

<br />

120,123,<br />

166-167<br />

118,<br />

121-122<br />

<br />

<br />

210<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com