Girder Tiedowns – HUGT series<br />

The HUGT series high uplift girder tiedowns can be installed on<br />

beams and top chords of trusses with slopes from 0° to 34°.<br />

Truss & Rafter<br />

Materials: 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

<strong>Installation</strong>:<br />

• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />

• Install the HUGT over the beam or truss (see “W” dimension<br />

on chart for appropriate width).<br />

• Install (4) LBP58-TZ washers if (2) 5/8˝ tension bolts are<br />

used (wood installation) or (2) 3/4˝ dia. washers if a 3/4˝ dia.<br />

anchor bolt is used (concrete installation).<br />

• Attached members shall be designed to resist applied loads.<br />

• Moisture barrier may be required.<br />

Concrete <strong>Installation</strong><br />

(2) 3 /4˝ washers are<br />

required if 3 /4˝ dia. bolt is<br />

used (washer not included)<br />

Wood <strong>Installation</strong><br />

(4) LBP58-TZ washers<br />

are required if 5 /8˝ dia.<br />

bolt is used (washer not<br />

included) see chart on<br />

this page<br />

HTT5<br />

(not included)<br />

see page 45<br />

Typical HUGT3<br />

wood-to-wood<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical HUGT2<br />

wood-to-concrete<br />

installation<br />

2 7 /8˝<br />

4˝<br />

W<br />

2 3 /16˝<br />

HUGT<br />

<strong>USP</strong><br />

Stock No.<br />

HUGT2<br />

HUGT3<br />

HUGT4<br />

Fastener Schedule 3<br />

Factored Uplift Resistance (115%) 1,2<br />

O.C. Dim<br />

W<br />

Anchor Washers Threaded Rod DF-L<br />

S-P-F<br />

Steel<br />

Between <strong>Installation</strong><br />

Girder 4,6<br />

Ref. No. Gauge (in) Anchors (in) Type Qty Type Qty Dia. Qty Type Lbs kN Lbs kN<br />

HGT-2<br />

HGT-3<br />

HGT-4<br />

7<br />

7<br />

7<br />

3-5/16<br />

4-15/16<br />

6-7/8<br />

5-3/4<br />

7-3/8<br />

9<br />

Wood<br />

Wood<br />

Wood<br />

4<br />

4<br />

4<br />

LBP58-TZ<br />

LBP58-TZ<br />

LBP58-TZ<br />

2<br />

2<br />

2<br />

5/8<br />

5/8<br />

5/8<br />

Concrete<br />

Concrete<br />

Concrete<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

2<br />

2<br />

2<br />

3/4<br />

3/4<br />

3/4<br />

8<br />

8<br />

8<br />

10d<br />

10d<br />

10d<br />

18575<br />

18575<br />

18575<br />

82.63<br />

82.63<br />

82.63<br />

9365<br />

9365<br />

9365<br />

41.66<br />

41.66<br />

41.66<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Factored resistances apply where roof pitch is between 3:12 and 8:12.<br />

3) Additional anchorage products to be designed by others.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

5) Designer must specify anchor bolt type, length, and embedment.<br />

6) NAILS<br />

156<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com