Top Flange Hangers – MPH, PHM, & PHXU series cont.<br />

L<br />

H<br />

TF<br />

L<br />

H<br />

3 3 /4˝<br />

L<br />

H<br />

TF<br />

EWP Hangers<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Series<br />

PHM<br />

W<br />

PHXU<br />

<br />

PHXU<br />

<br />

PHM<br />

D<br />

Fastener Schedule 3<br />

W<br />

MPH<br />

2 1 /2˝<br />

W<br />

PHXU<br />

PHM & PHXU Nailer Options – chart represents maximum factored resistance<br />

for hangers used on wood nailers. Reference page 117.<br />

Factored Resistance 2<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Nailer<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Size Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2X 2 10d x 1-1/2 2 10d x 1-1/2 4335 -- -- 19.28 -- -- 3730 -- -- 16.59 -- --<br />

3X 2 16d x 2-1/2 2 10d x 1-1/2 5140 -- -- 22.86 -- -- 4420 -- -- 19.66 -- --<br />

(2) 2X 2 10d 2 10d x 1-1/2 4790 -- -- 21.31 -- -- 4120 -- -- 18.33 -- --<br />

4X 2 16d 2 10d x 1-1/2 4685 -- -- 20.84 -- -- 4030 -- -- 17.93 -- --<br />

4X 8 16d 6 10d x 1-1/2 6370 1210 28.34 5.38 4420 920 19.66 4.09<br />

4X 8 16d 6 10d x 1-1/2 7610 1005 33.85 4.47 5170 865 23.00 3.85<br />

4X 8 16d 6 10d 7610 1290 33.85 5.74 5170 1150 23.00 5.12<br />

<br />

<br />

<br />

3) NAILS<br />

red font.<br />

D<br />

Typical PHXU<br />

installation<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option <strong>USP</strong> Series Skewed 1,3,5 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Sloped Top Flange 4 Top Flange Offset 5,7 Saddle 5,6 Ridge<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

PHM <br />

<br />

<br />

PHXU<br />

<br />

<br />

N/A<br />

<br />

<br />

MPH N/A N/A<br />

PHM<br />

PHXU<br />

MPH<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

7) PHXU offset option - hanger will be welded with a closed top angle, not formed.<br />

red font.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

See footnote 6.<br />

<br />

SA,<br />

DA, and<br />

SK,<br />

SL,<br />

SF,<br />

OS, and<br />

<br />

<br />

PHM <br />

(R) (L), <br />

(R) (L), (U) (D),<br />

<br />

(R) (L),<br />

<br />

<br />

PHXU<br />

<br />

N/A<br />

<br />

MPH N/A N/A<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 127<br />