Heavy-Duty Face Mount Truss Hangers – THD series<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Materials: See chart<br />
Finish: G90 galvanizing<br />
Options: THD28-2, THD46, THD48, & THD410 are available in<br />
Triple Zinc. To order, add TZ to stock number, as in<br />
THD28-2TZ.<br />
See Specialty Options Chart. Rough/Full sizes<br />
available. THD hangers with widths greater than 3˝ can<br />
have one flange inverted with no load reduction. Specify<br />
right (R) or left (L).<br />
Codes: Load values are derived from data submitted to various<br />
North American building code evaluators.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
See EWP applications page 122<br />
Dimensions (in) Fastener Schedule 2,3<br />
Header Joist<br />
W<br />
THD28<br />
A<br />
D<br />
H<br />
Typical THD210<br />
installation<br />
Joist /<br />
<strong>USP</strong><br />
Steel<br />
Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />
Truss Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />
2 x 6 - 8 THD26 HTU26 16 1-5/8 5-1/16 3 1-7/8 18 16d 12 10dx1-1/2 5010 4390 22.29 19.53 3557 3117 15.82 13.87<br />
2 x 8 - 10 THD28 HTU28 16 1-5/8 7 3 1-7/8 28 16d 16 10dx1-1/2 6495 4390 28.89 19.53 4611 3117 20.51 13.87<br />
2 x 10 - 12 THD210 HTU210 16 1-5/8 9 3 1-7/8 38 16d 20 10dx1-1/2 8380 5835 37.28 25.96 5950 4143 26.47 18.43<br />
(2) 2 x 6 - 8 THD26-2<br />
HHUS26-2,<br />
HTU26-2<br />
14 3-7/16 5-3/8 3 2 18 16d 12 10d 7090 5745 31.54 25.56 5034 4079 22.39 18.14<br />
(2) 2 x 8 - 10 THD28-2<br />
HHUS28-2,<br />
HTU28-2<br />
14 3-7/16 7-1/8 3 2 28 16d 16 10d 8195 4885 36.45 21.73 5818 3468 25.88 15.43<br />
(2) 2 x 10 - 12 THD210-2<br />
HHUS210-2,<br />
HTU210-2<br />
14 3-7/16 9-1/8 3 2 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />
4 x 6 - 8 THD46 HHUS46 14 3-5/8 5-5/16 3 2 18 16d 12 10d 7090 5745 31.54 25.56 5034 4079 22.39 18.14<br />
4 x 8 - 10 THD48 HHUS48 14 3-5/8 7-1/16 3 2 28 16d 16 10d 8195 4885 36.45 21.73 5818 3468 25.88 15.43<br />
4 x 10 -12 THD410 HHUS410 14 3-5/8 9-1/16 3 2 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />
4 x 12 - 14 THD412 -- -- 14 3-5/8 11 3 3 48 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />
4 x 14 - 16 THD414 -- -- 14 3-5/8 12-7/8 3 3 58 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />
(3) 2 x 10 - 12 THD210-3 HHUS210-3 12 5-1/8 9 3 3 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />
6 x 10 -12 THD610 HHUS5.50/10 12 5-1/2 9 3 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />
6 x 12 - 14 THD612 -- -- 12 5-1/2 11 3 3 48 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />
6 x 14 - 16 THD614 -- -- 12 5-1/2 12-7/8 3 3 58 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />
7 x 9-1/4 - 14 THD7210 HHUS7.25/10 12 7-1/4 9 3 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />
3) NAILS<br />
Some model designs may<br />
vary from illustration shown<br />
Factored Resistance<br />
DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />
Plated Truss<br />
Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />
Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />
<br />
Range<br />
See Sloped Seat and Skewed Widths > 3 can have<br />
one flange inverted.<br />
100% of table value.<br />
Factored<br />
65% of table value when<br />
85% of table value 65% of table value 65% of table value<br />
Resistance<br />
nailing into the support<br />
members end grain.<br />
Ordering<br />
Add SK, angle required,<br />
and right (R) or left (L),<br />
to product number.<br />
Ex. THD410-SK45R<br />
Add SL, slope required,<br />
and up (U) or down (D),<br />
to product number.<br />
Ex. THD410-SL30D<br />
See Sloped Seat and Skewed.<br />
Ex. THD410-SK45RSL30D<br />
Add 1IF, one flange,<br />
right (R) and left (L),<br />
to product number.<br />
Ex. THD4101IFR<br />
Left<br />
flange<br />
W<br />
D<br />
A<br />
H<br />
Right<br />
flange<br />
1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />
2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />
3) All sloped, skewed, or combinations require bevel cut on joist in all applications.<br />
THD28-2<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com 165<br />
<strong>USP</strong>2240-131