Roof Truss Ties – TR series<br />
Slotted design allows truss to deflect without imposing load on wall below.<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />
Fastener Schedule 6,7 S-P-F<br />
Factored Resistance (115%) 1<br />
Truss Plate DF-L<br />
<strong>USP</strong><br />
Steel<br />
Without Gap 2 3 4 Without Gap 2 3 4<br />
Stock No. Ref. No. Gauge Description Qty Type Qty Type Unit F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2<br />
TR1<br />
<br />
Lbs 105 60 45 45 -- -- -- -- 90 50 35 35 -- -- -- --<br />
18 single slot 1 8d 2 8d<br />
<br />
kN 0.47 0.27 0.20 0.20 -- -- -- -- 0.40 0.22 0.16 0.16 -- -- -- --<br />
TR1T<br />
TR2<br />
<br />
DTC<br />
16<br />
18<br />
single slot<br />
double slot<br />
1<br />
2<br />
8d<br />
8d<br />
2<br />
4<br />
8d<br />
8d<br />
Lbs<br />
Lbs<br />
375<br />
155<br />
-- --<br />
260<br />
205<br />
105<br />
-- --<br />
170<br />
125<br />
-- --<br />
-- --<br />
-- --<br />
320<br />
130<br />
-- --<br />
220<br />
175<br />
90<br />
-- --<br />
140<br />
110<br />
-- --<br />
-- --<br />
-- --<br />
kN<br />
kN<br />
1.67<br />
0.69<br />
-- --<br />
1.16<br />
0.91<br />
0.47<br />
-- --<br />
0.76<br />
0.56<br />
-- --<br />
-- --<br />
-- --<br />
1.42<br />
0.58<br />
-- --<br />
0.98<br />
0.78<br />
0.40<br />
-- --<br />
0.62<br />
0.49<br />
-- --<br />
-- --<br />
-- --<br />
1) Factored resistances have been increased for short-term loading; 5) To achieve F1 loads in both directions, clips must be installed on<br />
no further increase is allowed. both sides of the trussand staggered to avoid nail interference.<br />
2) Truss must be bearing on top plate to achieve the factored resistances 6) Minimum nail embedment shall be 8 nail diameters (typ).<br />
under "Without Gap". 7) NAILS:<br />
New products or updated product information are designated in red font.<br />
<br />
<br />
<br />
<strong>USP</strong><br />
Stock No.<br />
HTC4<br />
Materials:<br />
Finish:<br />
See chart<br />
G90 galvanizing<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Do not fully set nails.<br />
• Locate nails into the centre of slots.<br />
Heavy Truss Deflection Clip – HTC4<br />
Slotted design allows truss to deflect without imposing load on wall below.<br />
Materials:<br />
Finish:<br />
Codes:<br />
16 gauge<br />
G90 galvanizing<br />
Load values are derived from data submitted to various<br />
North American building code evaluators.<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
• Do not fully set nails.<br />
Fastener Schedule 2,4,5<br />
Plate Truss/Rafter<br />
Without Gap 3<br />
Factored Resistance (115%) 1<br />
3<br />
Without Gap 3 3<br />
Top Side<br />
F1 F2 F1 F2 F1 F2 F1 F2<br />
Steel<br />
Ref. No. Gauge Qty Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />
HTC4,<br />
16 2 4 10d x 1-1/2 3 10d x 1-1/2 265 1.18 545 2.42 55 0.24 305 1.36 230 1.02 470 2.09 45 0.20 260 1.16<br />
S/HTC4<br />
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />
2) Truss/Rafter must be bearing on top plate to achieve the allowable loads under "Without Gap".<br />
3) When installed with maximum 1-1/4" space between truss/rafter and top plate, use loads under "With 1-1/4" Gap".<br />
4) Minimum nail embedment shall be 8 nail diameters (typ).<br />
5) NAILS<br />
Blocking Supports – ZC series<br />
DF-L<br />
D<br />
S-F-P<br />
3 1 /2˝<br />
TR2<br />
2 1/2˝ 2 11/16˝ F2<br />
1 7/8˝<br />
F1<br />
Typical TR2 installation<br />
HTC4<br />
3 1 /4˝<br />
1 15 /16˝<br />
TR1<br />
1˝<br />
1 1/4˝ 2 3/4˝<br />
2˝<br />
F2<br />
NEW<br />
SIZE<br />
1 1 /4˝<br />
TR1T<br />
F1<br />
Typical HTC4<br />
installation<br />
4 1 /4˝<br />
1 3/4˝<br />
Plated Truss<br />
ZC clips secure blocking between joists or trusses which<br />
provides support for drywall or sheathing.<br />
Materials:<br />
Finish:<br />
See chart<br />
G90 galvanizing<br />
<strong>Installation</strong>:<br />
• Use all specified fasteners. See Product <strong>Notes</strong>, page 10.<br />
1) Factored resistance shall not be increased for other load duration factors.<br />
2) Minimum nail embedment shall be 8 nail diameters (typ).<br />
3) NAILS:<br />
red font.<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />
ZC4<br />
179<br />
<strong>USP</strong>2240-131<br />
H<br />
W<br />
ZC2<br />
Dimensions (in)<br />
Fastener Schedule 2,3<br />
Factored Resistance 1<br />
Header Blocking DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />
<strong>USP</strong><br />
Steel<br />
Vertical Vertical Vertical Vertical<br />
Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 100% 100% 100%<br />
ZC2 Z2 20 2-1/4 1-9/16 1-1/2 2 10d x 1-1/2 2 10d x 1-1/2 670 2.98 475 2.11<br />
ZC4 Z4 12 1-1/2 3-9/16 1-3/8 2 10d x 1-1/2 1 10d x 1-1/2 460 2.05 385 1.71<br />
ZC24 Z28 28 2-1/2 1-9/16 1-3/8 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />
ZC34 Z38 28 2-1/2 2-9/16 1-5/16 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />
Typical ZC installation