2 Command System RIGOL<br />

:CURSor:MANual:BXValue<br />

Syntax<br />

:CURSor:MANual:BXValue<br />

Description<br />

Query the X value at cursor B in manual cursor measurement.<br />

Explanation<br />

For the horizontal position of cursor B, refer to the :CURSor:MANual:CBX command.<br />

The unit is determined by the horizontal unit currently selected (refer to<br />

the :CURSor:MANual:TUNit command).<br />

Return Format<br />

The query returns the X value at cursor B in scientific notation.<br />

Example<br />

:CURSor:MANual:BXValue<br />

The query returns 5.120000e-06.<br />

<strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong> 2-151