2 Command System RIGOL<br />

:MEASure:RTIMe<br />

Syntax<br />

:MEASure:RTIMe <br />

Description<br />

Query the measurement value of the rise time of the selected waveform and the unit<br />

is s.<br />

Parameter<br />

Name Type Range Default<br />

Discrete {CHANnel1|CHANnel2} CHANnel2<br />

Return Format<br />

The query returns the measurement result in scientific notation.<br />

Example<br />

:MEASure:RTIMe CHANnel1<br />

The query returns 3.080000e-04.<br />

You can use the following commands to query the statistic maximum, minimum,<br />

current value, average and standard deviation of the rise time measurement values<br />

of the selected waveform. Sending the following commands will enable the statistic<br />

function automatically.<br />

• :MEASure:RTIMe:SMAXimum<br />

• :MEASure:RTIMe:SMINimum<br />

• :MEASure:RTIMe:SCURrent<br />

• :MEASure:RTIMe:SAVerage<br />

• :MEASure:RTIMe:SDEViation<br />

<strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong> 2-333