20.01.2015 Views

Programming Guide DS2000 Series Digital Oscilloscope

Programming Guide DS2000 Series Digital Oscilloscope

Programming Guide DS2000 Series Digital Oscilloscope

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 Command System RIGOL<br />

:TRIGger:SLOPe:WINDow<br />

Syntax<br />

:TRIGger:SLOPe:WINDow <br />

:TRIGger:SLOPe:WINDow<br />

Description<br />

Set the type of the vertical window in slope trigger.<br />

Query the current type of the vertical window in slope trigger.<br />

Parameter<br />

Name Type Range Default<br />

Discrete {TA|TB|TAB} TA<br />

Explanation<br />

Different vertical windows correspond to different trigger level adjustment modes.<br />

TA: only adjust the upper limit of the trigger level. Refer to<br />

the :TRIGger:SLOPe:ALEVel command.<br />

TB: only adjust the lower limit of the trigger level. Refer to<br />

the :TRIGger:SLOPe:BLEVel command.<br />

TAB: adjust the upper and lower limits of the trigger level at the same time. Refer to<br />

the :TRIGger:SLOPe:ALEVel and :TRIGger:SLOPe:BLEVel commands.<br />

Return Format<br />

The query returns TA, TB or TAB.<br />

Example<br />

:TRIGger:SLOPe:WINDow TB<br />

The query returns TB.<br />

<strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong> 2-471