RIGOL<br />

2 Command System<br />

:BUS:PARallel:OFFSet<br />

Syntax<br />

:BUS:PARallel:OFFSet <br />

:BUS:PARallel:OFFSet<br />

Description<br />

Set the vertical offset in parallel decoding on bus 1 or 2. Enable the display of the bus<br />

(refer to the :BUS:DISPlay command), before using this command.<br />

Query the current vertical offset in parallel decoding on bus 1 or bus 2.<br />

Parameter<br />

Name Type Range Default<br />

Discrete {1|2} --<br />

Integer<br />

Normal [1] : -166 to 148<br />

Statistic [2] : -163 to 143 0<br />

Half screen [3] : -103 to 52<br />

Note [1] : the screen display is normal and the statistic function is not enabled (refer to<br />

the :MEASure:STATistic:DISPlay command).<br />

Note [2] : the screen display is normal and the statistic function is enabled (refer to<br />

the :MEASure:STATistic:DISPlay command).<br />

Note [3] : the screen is divided into two windows (refer to the :TIMebase:DELay:ENABle<br />

and :CALCulate:FFT:SPLit commands).<br />

Return Format<br />

The query returns the offset in integer.<br />

Example<br />

:BUS1:PARallel:OFFSet 2<br />

The query returns 2.<br />

2-38 <strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong><br />

2-38