RIGOL<br />

2 Command System<br />

:TRIGger:NEDGe:LEVel<br />

Syntax<br />

:TRIGger:NEDGe:LEVel <br />

:TRIGger:NEDGe:LEVel<br />

Description<br />

Set the trigger level in Nth edge trigger and the unit is the same with the current<br />

amplitude unit.<br />

Query the current trigger level in Nth edge trigger.<br />

Parameter<br />

Name Type Range Default<br />

Real<br />

± 5 × VerticalScale from the screen center -<br />

OFFSet<br />

0<br />

Note:<br />

For VerticalScale, refer to the :CHANnel:SCALe command.<br />

For the OFFSet, refer to the :CHANNel:OFFSet command.<br />

Return Format<br />

The query returns the trigger level in scientific notation.<br />

Example<br />

:TRIGger:NEDGe:LEVel 0.16<br />

The query returns 1.600000e-01.<br />

2-464 <strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong><br />