2 Command System RIGOL<br />

:MEASure:FPHase:SMINimum<br />

Syntax<br />

:MEASure:FPHase:SMINimum ,<br />

Description<br />

Query the statistic minimum of the measurement results of the phase deviation<br />

between channels (relative to the falling edge) and the unit is °.<br />

Parameter<br />

Name Type Range Default<br />

Discrete {CHANnel1|CHANnel2} CHANnel1<br />

Discrete {CHANnel1|CHANnel2} CHANnel2<br />

Return Format<br />

The query returns the measurement result in scientific notation.<br />

Example<br />

:MEASure:FPHase:SMINimum CHANnel1,CHANnel2<br />

The query returns -1.792829e+02.<br />