2 Command System RIGOL<br />

:TRIGger:RUNT:BLEVel<br />

Syntax<br />

:TRIGger:RUNT:BLEVel <br />

:TRIGger:RUNT:BLEVel<br />

Description<br />

Set the lower limit of the trigger level in runt trigger and the unit is the same with the<br />

current amplitude unit.<br />

Query the current lower limit of the trigger level in runt trigger.<br />

Parameter<br />

Name Type Range Default<br />

Real<br />

± 5 × VerticalScale from the screen center -<br />

OFFSet<br />

0<br />

Note:<br />

For the VerticalScale, refer to the :CHANnel:SCALe command.<br />

For the OFFSet, refer to the :CHANNel:OFFSet command.<br />

Return Format<br />

The query returns the lower limit of the trigger level in scientific notation.<br />

Example<br />

:TRIGger:RUNT:BLEVel 0.16<br />

The query returns 1.600000e-01.<br />