RIGOL<br />

2 Command System<br />

:MEASure:SETup:MID<br />

Syntax<br />

:MEASure:SETup:MID <br />

:MEASure:SETup:MID<br />

Description<br />

Set the middle value of threshold measurement and the unit is %.<br />

Query the current middle value of threshold measurement.<br />

Parameter<br />

Name Type Range Default<br />

Integer 6 to 94 50<br />

Explanation<br />

The threshold is the vertical level (in percentage) being measured in the analog<br />

channel. Setting the threshold will affect all the time, delay and phase measurement<br />

parameters.<br />

You can use the :MEASure:SETup:TYPE command to select the threshold<br />

measurement setting.<br />

The middle value set must be lower than the upper limit currently set (refer to the<br />

MEASure:SETup:MAX command) and greater than the lower limit currently set (refer<br />

to the MEASure:SETup:MIN command).<br />

Return Format<br />

The query returns an integer between 6 and 94.<br />

Example<br />

:MEASure:SETup:MID 94<br />

The query returns 94.<br />

2-260 <strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong><br />

2-260