RIGOL<br />

2 Command System<br />

:BUS:PARallel:CLK<br />

Syntax<br />

:BUS:PARallel:CLK <br />

:BUS:PARallel:CLK<br />

Description<br />

Set the clock channel source of parallel decoding on bus 1 or 2.<br />

Query the current clock channel source of parallel decoding on bus 1 or 2.<br />

Parameter<br />

Name Type Range Default<br />

Discrete {1|2} --<br />

Discrete {CHANnel1|CHANnel2|OFF} OFF<br />

Explanation<br />

When OFF is selected, no clock channel is set and the oscilloscope samples data once<br />

the channel data jumps. At this point, the edge set by the :BUS:PARallel:SLOPe<br />

command can be ignored.<br />

Return Format<br />

The query returns CHAN1, CHAN2 or OFF.<br />

Example<br />

:BUS1:PARallel:CLK CHANnel2<br />

The query returns CHAN2.<br />

2-34 <strong>DS2000</strong> <strong>Programming</strong> <strong>Guide</strong><br />