15.11.2012 Views

User Manual - Ajckids.com

User Manual - Ajckids.com

User Manual - Ajckids.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fixing Bugs<br />

When you see the screen as per Figure 114 the rescue mode<br />

is active. Now you can start installing the operating system via<br />

the web interface. You can influence the IP settings.<br />

25.1.1.1. Rescue system via DHCP<br />

If you use a DHCP server (also refer to chapter 24.1.) you can<br />

force the rescue system to take the IP address from this server.<br />

• Disconnect your <strong>com</strong>mand station from the mains.<br />

• Press the stop button and the function button F8 of the left cab<br />

simultaneously and hold them down.<br />

Figure 122<br />

• Switch on your <strong>com</strong>mand station.<br />

Please hold down both buttons during the start-up of your<br />

<strong>com</strong>mand station (screen as per figure 121 will open).<br />

25.1.1.2. Rescue system via Static IP<br />

You can force the rescue system to accept a preset IP address.<br />

This option should only be used by experienced <strong>com</strong>puter specialists.<br />

The IP address is 192.168.1.151 /24.<br />

• Disconnect your <strong>com</strong>mand station from the mains.<br />

• Press the stop button and the function button F7 of the left cab<br />

simultaneously and hold them down.<br />

Figure 123<br />

• Switch on your <strong>com</strong>mand station.<br />

Please hold down both buttons during the start-up of your<br />

<strong>com</strong>mand station (screen as per figure 121 will open).<br />

25.2. Execute a factory reset<br />

In many cases technical problems with the software are not<br />

actually caused by the incorrect installation of the software but<br />

rather by errors in the lists of lo<strong>com</strong>otives, accessories, routes<br />

or the track diagrams. Such errors in the so called ”Play status”<br />

can lead to unusual behaviour of the <strong>com</strong>mand station.<br />

In the worst case the <strong>com</strong>mand station gets stuck during startup<br />

and the screen remains blank.<br />

If this is the case you should first delete all lists that contain<br />

objects. Such a factory reset can be ac<strong>com</strong>plished during the<br />

start-up phase.<br />

• Disconnect your <strong>com</strong>mand station from the mains.<br />

• Press the stop button and the function button F6 of the left cab<br />

simultaneously and hold them down<br />

Figure 124<br />

• Switch on your <strong>com</strong>mand station.<br />

• Hold down the buttons during the start-up phase until the<br />

“Go” button blinks shortly.<br />

Do not mistake the function of the rescue mode with the<br />

factory reset. Always try to re-establish the <strong>com</strong>mand station<br />

with a reset first. Basically the rescue mode must only be activated<br />

whenever a software update went wrong (for instance<br />

due to a power interruption during the update).<br />

41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!