152For repeated measurements.Calibration can be repeated untilthe desired degree of accuracy isreached.Three measurement arerecommended.Calculates the ATR accuracyfrom the current measuredvalues. It is only posible with atleast 2 measurements in 2 faceswere made.ATR-COLLIMATION RESULTHz : -0.0738 gHz (old) : +0.0000 gV : -0.0738 gV (old) 0.0000 gSet the new calibrated values.Function is interrupted and thecalibration values are retained.