154Messages Meaning Measures to takeVertical angle not suited foradjustment.No prism were found or theweather is bad.Several prism were found.Exact positioning is notpossible.Instrument is turning.The vertical angle may not deviateby more than +/- 10g from thehorizontal during calibration.This message may be displayedin bad weather (e.g. in fog) or ifthe prism is too far away.Several prism are in the field ofview of the telescope during ATRsearch.A runtime error while positioninghas occured. Heat flickering or aninstable prism location arepossible causes.The instrument changes face andpositions itself automatcally on thereflector.Adjust reflector height to enableapprox. horizontal sigthing.The prism has to be aimed atmore exactly and themeasurement repeated. The ATRmay be switched off, too.The target prism must beaimed at more exactly and themeasurement repeated.Repeat the measurements.During this interval do not manuallymove the alhidade or the drives.