RIDSDALE PEEL-BACK TESTER (cont’d)IIPURPOSE: (cont’d)(c)(d)(e)Transfer the sample to the stainless steel funnel, placing a finger over the bottom ofthe funnel to restrict sand flow.Swing the funnel over to the centre of the hot plate and release the sand sample ontothe plate. Leave for 18 seconds and then invert the hot plate 180° and allow to setfor an additional one minute.After one minute weigh the material that has been collected in the tray on the bottomof the machine and subtract this weight from the sample weight used to give you apercentage peel.112