12.07.2015 Views

Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4 Burner4.4 Third party burners4.4.1 Burner requirementsObserve the installation instructions issued by the burnermanufacturer where the burner installation is concerned.D FRD maxL TT 14.4.2 Third party burners for <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>floor standing gas condensing boilersMatched and approved pressure-jet gas burners arerecommended for the <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> floor standinggas condensing boilers. The can be fitted directly to theprepared burner door.Hole dimensions:• Up to 70 kW:– Hole circle diameter 150 mmThreaded holes 4 × M8 (45°)Flame tube hole 110 mm• From 90 kW:– Hole circle diameter 170 mmThreaded holes 4 × M8 (45°)Flame tube hole 130 mmL FRFig. 28 Burner installation dimensionsD FR Combustion chamber diameterD max Maximum blast tube diameterL FR Combustion chamber lengthL T Door depthT 1 Minimum depth, blast tube6 720 642 881-27.1il4.4.3 Third party burners for <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong>and <strong>SB745</strong> floor standing gas/oilcondensing boilersMatched and approved pressure-jet gas burners arerecommended for the <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong> and <strong>SB745</strong>floor standing condensing boilers. A burner plate drilledfor installation of the right burner is available as anaccessory. Alternatively, the holes can be drilled on site inthe dummy burner plate, available separately.Boiler sizeBlast tube dimensionsMinimumdepth T 1MaximumdepthMaximumdiameter D max[mm] [mm] [mm]50–70 45 95 10990–115 70 120 129145–310 185 235 247400 185 235 279510–640 185 235 319800–1200 210 260 350Table 13 Blast tube dimensions for <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>,<strong>SB615</strong> and <strong>SB745</strong> floor standing condensingboilers36Technical guide Floor standing gas/oil condensing boilers <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong>, <strong>SB745</strong> – 6 720 802 589 (2012/01)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!