12.07.2015 Views

Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical description33 Technical description3.1 <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong> and <strong>SB745</strong> floor standing gas and oil condensingboilers3.1.1 Equipment overviewThe <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong> and <strong>SB745</strong> floorstanding gas and oil condensing boilers are consistentlydesigned with stainless steel heating surfaces forcondensing technology. They are tested to EN 15417and EN 15034, type-tested and CE-designated. Qualityassurance measures to DIN ISO 9001 andDIN EN 29001 contribute to the high manufacturingquality and functional reliability.The conditions for the DVGW quality markare met. Additionally, the Unit version of the<strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> VM and <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong> VMfloor standing gas condensing boiler with Logatop VMmodulating premix gas burner from <strong>Buderus</strong> significantlyreduces the sound emissions.The cover of the <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong> boiler has a loadbearingcapacity of 100 kg/m 2 .<strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>The floor standing condensing boilers in this series areavailable:• With outputs of 50 kW to 115 kW (50/30 °C)• Versions:– <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> gas:Unit version <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> gas VM withLogatop VM low emissions modulating premix gasburner from <strong>Buderus</strong> for natural gas (E/LL) or LPG– <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> gas without burner:For the use of approved pressure-jet gas burners fornatural gas (E/LL) or LPG– <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> oil/gas:Unit version <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> oil/gas BE-A withLogatop BE-A blue flame oil burner from <strong>Buderus</strong>(boiler size 50–70),Unit version <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> oil/gaswith pressure-jet oil burner from Weishaupt or Riellofor low sulphur fuel oil EL and fuel oil EL A Bio 10 toDIN 51603 (boiler size 90–115)– <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> oil/gas without burner:For the use of approved pressure-jet oil and gasburners for low sulphur fuel oil EL and fuel oil EL ABio 10 to DIN 51603, natural gas (E/LL), LPG ordual fuel burner6 720 642 881-03.1ilFig. 4<strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong> VM floor standing gascondensing boiler with extremely quiet premixgas burner and Logamatic 4211 control unitTechnical guide Floor standing gas/oil condensing boilers <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong>, <strong>SB745</strong> – 6 720 802 589 (2012/01) 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!