Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

Logano plus SB315, SB615, SB745 - Buderus

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9 InstallationSafety component Make Component designationLow water indicator Sasserath SRY 09333.20.011 TÜV HBW-96-190Maximum pressure limiter Sauter DSH 143 F 001 SDB.00-331Minimum pressure limiter Sauter DSL 143 F 001 SDBF-00-330High limit safety cut-out (STB) Sauter RAK 13.5050 B TÜV ID: 0000006982Minimum pressure switch Fatini Cosmi2B01ATF0.8 WB40286519Table 43 Approval designations of safety components for the <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong> and <strong>SB745</strong> floor standingcondensing boilers9.5.3 Boiler safety valve assembly to DIN EN 12828An intermediate flow piece and valve distributorare required to install the safety equipment at the<strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong>.• Versions: DN65/80/100/125• Type approval number: 06-226-6715 6 7ConnectionH[mm]DN65 462DN80 500DN100 552Table 44 Height of the boiler safety valve assembly forthe <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong> floor standingcondensing boilers43289HThe standard delivery of the boiler safety equipmentassembly includes a complete gasket set and installationinstructions.1370150 1501 2 311103506 720 642 881-34.1ilFig. 51 Boiler safety valve assembly to DIN EN 12828(intermediate flow piece with valve distributorand valves) for the <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong> floorstanding condensing boilers (dim. in mm)Fig. 504 6 720 642 881-35.1ilValve distributor for installation on theintermediate flow piece of the boiler safetyvalve assembly for the <strong>Logano</strong> <strong>plus</strong> <strong>SB615</strong>floor standing condensing boilers (dim. in mm)1 Connection for maximum pressure limiter (½ ")2 Connection for 2nd maximum pressure limiter (½ ")3 Connection for pressure gauge (½ ")4 Connection of valve distributor and intermediate flow piecevia cap valve with BDF valve (adaptor from 1" to ¾ ")1 Intermediate flow piece2 Sensor pocket with thermometer3 Automatic air vent valve4 Valve manifold5 Connection for maximum pressure limiter (½ ")6 Connection for 2nd maximum pressure limiter (½ ")7 Pressure gauge shut-off valve with test device andpressure gauge8 Connection for pressure gauge (½ ")9 Connection of valve distributor and intermediate flow piecevia cap valve with BDF valve (adaptor from 1" to ¾ ")10 Connection for temperature test device11 Connection for 2nd high limit safety cut-out82Technical guide Floor standing gas/oil condensing boilers <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong>, <strong>SB745</strong> – 6 720 802 589 (2012/01)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!