Flue system1010.1.4 Plastic flue systemFlue systems matched to the floor standing gascondensing boilers are available for positive pressureoperation up to DN315. These flue systems are madefrom polypropylene (PP). They have building regulationapproval [Germany] for flue gas temperatures up to120 °C. All systems are supplied ready to plug in; nowelding is required.Special boiler connection pieces are available to connectto the boiler.Legal requirementsWhen designing a flue system, consult the responsibleflue gas inspector. This inspector must approve the fluesystem.ApprovalThe products in the flue system meet the requirements ofEN 14471 and, even if the installation is different from thesystem certification, can be used in accordance withnational usage regulations and the product specificationson the CE certificate 0036 CPD 9169 003.The flue is suitable for:• Positive/negative pressure• Gas, standard/low sulphur fuel oil EL and fuel oilEL A Bio• Maximum permissible flue gas temperature 120 °C• Designation categoriesSingle wall: EN 14471 T120 H1 O W2 O20 I D LConcentric: EN 14471 T120 H1 O W2 O00 E D L0Minimum chimney shaft dimensionsFlue pipeinternaldiameterMinimum chimney shaftdimensionsRound chimneyshaft[mm]Rectangularchimney shaft[mm]DN110 Ø 160 140 × 140DN125 Ø 180 180 × 180DN160 Ø 200 200 × 200DN200 Ø 250 250 × 250DN250 Ø 330 310 × 310DN315 Ø 400 380 × 380Table 50 Minimum chimney shaft dimensions for theavailable plastic flue systemsChimney shaft requirementsInside buildings, flue systems must be run through achimney shaft (not required in adequately ventilatedinstallation rooms). This must be made from noncombustiblerigid material.Required fire resistance time:• 90 minutes (fire resistance category F90)• 30 minutes (fire resistance category F30, in singlestorey buildings).Any existing chimney that has been in use before must becleaned professionally and thoroughly prior to running theflue into it. This applies particularly to chimneys that areoperated in conjunction with combustion equipment forsolid fuel.Technical guide Floor standing gas/oil condensing boilers <strong>Logano</strong> <strong>plus</strong> <strong>SB315</strong>, <strong>SB615</strong>, <strong>SB745</strong> – 6 720 802 589 (2012/01) 93

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!