12.07.2015 Views

ABB i-bus® EIB Switch/dim actuator, FM Type: 6114 U-500

ABB i-bus® EIB Switch/dim actuator, FM Type: 6114 U-500

ABB i-bus® EIB Switch/dim actuator, FM Type: 6114 U-500

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ABB</strong> i-bus ® <strong>EIB</strong><strong>Switch</strong>/<strong>dim</strong> <strong>actuator</strong>, <strong>FM</strong><strong>Type</strong>: <strong>6114</strong> U-<strong>500</strong> + 6324-xxIR <strong>Switch</strong> Dim Shutter /1Selection in ETS2– <strong>ABB</strong>Push Button tritonPush button, 5-fold for 1SDAThe application program is intendedfor the 5-fold Busch-triton ® switchsensor application module inconnection with a switch/<strong>dim</strong> <strong>actuator</strong><strong>FM</strong>.The Busch-triton ® switch sensor can beused for switching, <strong>dim</strong>ming andshutter control.The rockers of the Busch-triton ® switchsensor each have the same set ofparameters. With the parameter“Operation mode of rocker”, the basicswitching, <strong>dim</strong>ming and shutter controlfunctions can be selected. Dependingon this setting, different parametersand objects are available for therockers. There is a common parameter“Push button action interpreted as longfrom” for all the rockers that are usedfor <strong>dim</strong>ming or shutter control.Normally, the switch sensor detects along push button action if a rocker ispressed for longer than 420 ms.BacklightingThe backlit text fields display thefunctions of the rockers even in thedark. Using the communication object“Backlighting/LED”, the backlightingand status LEDs can be switched on oroff if required.The auxiliary push button can also beused for manual switching. To do so,the parameter “Function of auxiliarypush button” must be set to“Backlighting and LED on/off”. Whenthe auxiliary push button is pressed,not only is the lighting of the switchsensor switched on or off but atelegram is sent via the communicationobject “Backlighting/LED”. It istherefore possible to switch on thelighting for several Busch-triton ® switchsensors at the same time via acommon group address.By default, the backlighting switcheson after bus voltage recovery. This canalso be changed via the parameter“Behaviour of backlighting at busrecovery”.Fault protectionThe auxiliary push button also makesthe fault protection function available.The fault protection function causesonly one basic function to be triggeredwhen any of the rockers of the switchsensor are pressed. For example,pressing one of the five rockers viacommunication object no. 1 “Faultprotection” switches the base lightingalternately on or off.The fault protection function can bepermanently activated or for examplebe timed to switch on or off via the <strong>EIB</strong>using object no. 0 “Fault protection Off/On”. If the parameter “Function ofauxiliary push button” is set to“Interrupt fault protection”, the rockerscan be used for different functionsaccording to their parameter settingsafter pressing the auxiliary push buttonfor approx. 5 seconds.Dimmer outputThe <strong>dim</strong>mer output has the threecommunication objects “Telegr. switch /switch”, “Tel. <strong>dim</strong>ming / rel. <strong>dim</strong>ming”and “Brightness value”. It can thus alsobe controlled by other sensors via the<strong>EIB</strong>. If a rocker of the Busch-triton ®switch sensor is parameterised as a<strong>dim</strong>ming sensor and thecommunication objects of the rockerare linked with those of the <strong>dim</strong>ming<strong>actuator</strong> via a group address, the<strong>actuator</strong> can also be operated locally.If the switch sensor is <strong>dim</strong>med up fromthe OFF state or switched on with abrightness value, it sends its newstatus on the <strong>EIB</strong> in the basic setting.The signal is carried out at theswitching and brightness valueobjects. This function is required forexample to switch on status LEDs.On receipt of an “On” telegram at the1 bit communication object, the<strong>actuator</strong> can switch on with minimumor maximum brightness. The valuescan be predefined with the parameter“<strong>Switch</strong> ON with”.8 - 122 March 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!